background image

 

Page 8

 
1.  Richard Riley, M.D. “Airborne Infection: The 

American Journal of Medicine, September 1974, Vol.

57 – 5/16/01 

 

 

P/N 46520200 09/06

 

2630 Airport Road, Kinston, NC 28504 

1-252-522-3031 • www.fieldcontrols.com

 

Summary of Contents for 46520200

Page 1: ... 1 Fiberglass Duct Board Mounting Bracket 1 UVC Light Shield 2 Wire Nuts 2 1 4 Male Quick Connect Terminals 2 Scotchlok Wire Taps The UV Aire unit is designed to emit powerful UVC Band light rays which sterilize and reduce airborne microorganisms as they pass through a heating or air conditioning system It is installed in the main supply or return duct and operates continuously to automatically pu...

Page 2: ...etergent Remove affected clothing immediately If skin surface is pierced seek medical attention immediately NOTE If you touch the glass of the lamp you should wipe the glass clean with isopropyl alcohol and a lint free wipe If the lamp is not cleaned the film of hand oils causes a reduction in the light intensity WARNING Before installing or servicing a humidifier air filter HVAC system or this un...

Page 3: ...s at positions indicated on template Refer to supplied template as shown in Figure 3 4 Cut out the large opening 1 1 2 hole on the template Refer to template as shown in Figure 3 5 Using a to drill bit drill a viewport hole as indicated on the template Figure 3 6 Optional Light Shield The light shield may be mounted at virtually any angle However when deciding on a suitable location the mounting s...

Page 4: ...d 120VAC electric supply Wire according to Diagram A or Diagram B Unit is designed to be wired to a 24V 40VA power supply only Check lamp operation by looking through the viewport hole NOTE The viewport hole is made of glass and will not allow any UVC rays to pass through A blue glow should be seen in the duct 13 If blue glow is not seen make sure the base is properly installed onto duct There is ...

Page 5: ...nds upon the environment Such as the type of air filter duration of use and replacement cycle 2 To maintain maximum output intensity replace the UV Aire lamp annually The lamp should operate continuously for maximum lamp life and light effectiveness Diagram B WARNING Never expose eyes or skin to UVC light from any source Looking directly at the UVC light may cause permanent eye damage or blindness...

Page 6: ...s contain a small amount of mercury like a typical fluorescent lamp Check with your local waste management authority for local disposal or recycling requirements According to the EPA s Universal Waste Rule these types of lamps may be disposed of into household waste WARNING Never touch broken lamp or internal contents of lamp The lamp contains mercury NOTE In case of accidental exposure to interna...

Page 7: ... a sealed garbage bag 4 Check with your local waste management authority for local disposal or recycling requirements According to the EPA s Universal Waste Rule these types of lamps may be disposed of into household waste 5 Wash hands and remove and wash clothes for added safety measures The health aspects associated with the use of these products and their ability to aid in disinfecting of envir...

Page 8: ...Page 8 1 Richard Riley M D Airborne Infection The American Journal of Medicine September 1974 Vol 57 5 16 01 P N 46520200 09 06 2630 Airport Road Kinston NC 28504 1 252 522 3031 www fieldcontrols com ...