2018.
Flex Cam
2·
14183·2000·
1
°
subject to alterations
11
Step 3: Order number of the Cam Unit
Select the Cam Unit according to the type of
operation to be performed. See also pages 8,10-12
Compact Cam:
2018.11.
.
Flange Cam:
2018.12.04000.049
Force Cylinder:
2018.30.
.
Example: The order number for the Compact Cam is
2018.11.04000.049
Transmission ratios in use
Transmission or reduction ratios can be expressed in
four different ways:
a) Force
b) Speeds of the individual Cam Units
c) Press travel speed to Cam Unit travel speed
d) Stroke lengths
Transmission ratios
The nominal transmission ratio of 1:1 is normally used
throughout the system.
The ratio can vary, however, according to the combi-
nation (and number) of Power Units and Cam Units
used (see table on page 10).
Selecting the components
The component sizes are explained step by step
below with regard to the forces required, stroke length
and the number of operations.
Step 1: Size of the Cam Unit
Calculate the force required for the operation to be
carried out. The Cam Unit used should provide suffi-
cient force to execute the operation. If the force requi-
red cannot be precisely calculated, we recommend
that you use a larger Cam Unit.
Force required (kN)
Cam Unit
0 – 15
2018.
.01500.
15 – 40
2018.
.04000.
40 – 60
2018.
.06000.
60 – 90
2018.
.09000.
90 –150
2018.
.15000.
Force required:
kN
Cam Unit size:
Example: If the force required is 22 kN, then a 40 kN Cam Unit
should be used. Cam Unit 2018.
.04000.
Step 2: Cam Unit stroke length
Determine the Cam Unit stroke required to execute the
operation in the tool. Use the Cam Unit with the shor-
test possible stroke, but remember that the tool must
have sufficient space for the workpiece.
Required stroke
Max. stroke length
length (mm)
of Cam Unit (mm)
Part number
0 – 25
25 (24)***
2018.
.
.025*
25 – 50
50 (49)***
2018.
.
.050*
50 –100
100 (99)**
/
***
2018.
.
.100*
*) 2018.11.
.024/049/099
**) This stroke length does not apply to Compact Cam
2018.11.01500.
***) Compact cam
Stroke length of Cam Unit:
mm
Example: If the stroke length required is 35 mm, use a Cam Unit
with a stroke length of 50 mm.
011_14119 29.08.2006 15:13 Uhr Seite 2
Summary of Contents for Flex Cam
Page 2: ...2 14176 2000 1 002_14112 29 08 2006 14 54 Uhr Seite 3...
Page 17: ...2 14191 2000 1 subject to alterations 17 017_14127 29 08 2006 15 16 Uhr Seite 2...
Page 23: ...2 14195 2001 2 subject to alterations 23 023_14131 30 08 2006 11 01 Uhr Seite 2...
Page 31: ...2 16287 2001 1 subject to alterations 31 031_16286 30 08 2006 7 11 Uhr Seite 2...
Page 37: ...2 14203 2001 2 subject to alterations 37 037_14139 30 08 2006 7 14 Uhr Seite 2...
Page 43: ...2 18714 2003 1 subject to alterations 43 043_18999 30 08 2006 7 19 Uhr Seite 2...
Page 68: ...2 14166 2 0 0 1 2 subject to alterations 66 066 30 08 2006 7 33 Uhr Seite 3...