Basic safety precautions should be observed. 

1. Ensure that incoming power is DISCONNECTED at the circuit breaker BEFORE any electrical

work is performed. 

2. A qualified electrician must install the FDS in accordance with all applicable National and 

Local Electrical Codes. 

3. Ensure that all lights to be connected to the FDS conform to the National Electrical Code 

(NEC) and all local codes and ordinances prior to connecting to the lights to the FDS. 

4. Do not exceed the maximum ratings of individual components, wiring devices, and current 

carrying capacity of conductors. 

5. The lighting circuit must have a Ground-Fault Circuit Interrupter (GFCI), and an appropriately 

rated circuit breaker. 

6. The FDS must be mounted at a minimum horizontally of 48” from edge of water, 8” minimum 

vertically above water level, and 4” minimum from the deck. 

7. The Light fixture and all metal items within five (5) feet of the pool, including this FDS, must 

be properly electrically bonded. 

8. This device should never operate an equipment that could cause property damage, bodily 

injury, or death should it be activated unexpectedly. 

9. Never allow children to operate the FDS unsupervised. 

IMPORTANT SAFETY INFORMATION 

FCC WARNING 

1. This device complies with Part 15 of the FCC Rules.  Operation is subject to the following 

two conditions: (1) this device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation. 

2. Changes or modifications not expressly approved by Fiberstars Inc. could void the user’s 

authority to operate the equipment. 

Summary of Contents for FDS

Page 1: ...79 15167 00 REV A www fiberstars com Page 1 of 10 FDS FDS R FDS PS USER MANUAL 3091594 ETL LISTED Conforms to UL STD 1241 For use with 120V 60Hz input Output is 120V 60Hz at 5amps 600W MAX switched...

Page 2: ...ircuit breaker 6 The FDS must be mounted at a minimum horizontally of 48 from edge of water 8 minimum vertically above water level and 4 minimum from the deck 7 The Light fixture and all metal items w...

Page 3: ...NOTE ALREADY INSTALLED DO NOT REMOVE FDS COVER PRINTED CIRCUIT BOARD ASSEMBLY FOR REMOTE OPERATION NOTE ALREADY INSTALLED DO NOT REMOVE FDS ROUND GASKET FDS ADAPTER PLATE FDS RECTANGULAR GASKET BRASS...

Page 4: ...ed for such applications STEP 5 Plug any unused conduit holes with the supplied conduit plugs STEP 6 Place the supplied rectangular gasket between the Brass base plate and the FDS adapter Important No...

Page 5: ...pgrading from a Thermocraft JBP57510 remove the FDS Adapter STEP 6 Place the Adapter gasket onto the Thermocraft base plate STEP 7 Wire the FDS according to STEP 7 in the FOR NEW INSTALLATIONS section...

Page 6: ...led within the 75 range of the remote transmitter STEP 2 Check the label of the FDS units to determine which operates on Circuit 1 and Circuit 2 STEP 3 To complete the installation follow instructions...

Page 7: ...itch is to test and trouble shoot the FDS x In the ON position the switch bypasses the FDS and turns on the light When in the ON position the Indicator Light should turn on at the same time x In the O...

Page 8: ...from ON to OFF and vice versa For Synchronization operation simply push the SYNC ON OFF button NOTE If all circuits are off when the SYNC ON OFF button is pressed all circuits will be turned to ON If...

Page 9: ...the Channel Code to match that of the FDS Reassemble the bottom cover to the top cover carefully Ensure that the bottom cover seats onto the top cover Screw down the mounting screws until they are snu...

Page 10: ...ight fails to come on go to STEP 4 MANUAL ON POSITION Pool light comes ON 4 Move Rocker switch to ON position If pool light comes on FDS or Remote Control is the problem 4a Replace batteries on Remote...

Reviews: