PoE Power Supply Budget Calculation 

Step1: Add Up The Demand For PoE In Watts

Add up the expected demand for power for each Powered Device (PD) in

watts.

Allow for the maximum power and upper end of PD classification. Any

unspecified devices should be assumed Class 0.

For example, an IEEE802.3af, Class 0 device may consume 9 watts; however, as

it’s

Class 0, assume 15.4 watts.

Round the numbers up

, occasionally, to account for the additional consumption of

the UTP (unshielded twisted-pair) ethernet cable that runs between the PD and PoE

switch.

For example, if an IEEE802.3at Class 4 IP camera consumes 25.5 watts, round to 30

watts, which adds a buffer to balance out the loss between the PoE switch and the

device.

Summary of Contents for FR-5A3010P

Page 1: ......

Page 2: ...ut should not be able to connect to each other Using this also improves network security 3 When AI QoS is enabled on the 8 port models Port 1 4 will prioritise Video and VoIP traffic flows over others...

Page 3: ...e letter A to A and B to B shown as below or A1 to A2 and B1 to B2 PoE Power Supply User Manual Item Specification PoE Port Port 1 to 8 IEEE802 3af at PoE Power Supply Pin Default 1 2 3 6 Optional 4 5...

Page 4: ...s 1000Base T RJ45 Connector Pin Assignment Pin MDI Signal Definition MDIX Signal Definition 1 BI_DA BI_DB BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_D...

Page 5: ...he data transmission and the cable should be safe The Power over Ethernet system works under the standardization of the Institute of Electrical and Electronics Engineers IEEE 802 3 committee Generally...

Page 6: ...wer to the PoE Switch Wiring Requirements Cable laying need to meet the following requirements 1 It is needed to check whether the type quantity and specification of cable match the requirement before...

Page 7: ...h Powered Device PD in watts Allow for the maximum power and upper end of PD classification Any unspecified devices should be assumed Class 0 For example an IEEE802 3af Class 0 device may consume 9 wa...

Page 8: ...ower supplies Take this harsh scenario for instance A switch and its power supply will be stored in a metal enclosure exposed to direct sun at a site in the northeastern United States In winter the te...

Page 9: ...Full Half Duplex Mode Auto MDI MDI X Connection Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X and 100BaseFX IEEE 802 3ab for 1000BaseT X IEEE 802 3z for 1000BaseSX LX LHX ZX IEEE 802 3x...

Page 10: ...y 5 90 non condensing Storage Temperature 20 70 4 to 158 MTBF 100 819 Hours MTBF Standard Telcordia SR 332 GB 25 Cooling Fanless Passive Cooling Noise Level 0 dBA Certification Warranty Lightning Prot...

Page 11: ...ent Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct t...

Reviews: