Installation Preparation
Before installation, confirm that the work environment meets the installation
requirements, including the power needs and abundant space. Whether it is close to
the connection equipment and other equipment are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or the area wherein
intense EMI.
2. Examine the cables and plugs that installation requirement.
3. Examine whether the cables be seemly or not (less than 100m) according to a
reasonable scheme.
4. Power: DC52V power input
5. Environment:
working temperature: 0
~
50
℃
(32 to 122
℉)
Storage Temperature: -20
~
70
℃ (
-4 to +158
℉)
Relative humidity 5%
~
95%
(
noncondensing
)
Desktop Installation
To Install a PoE Switch on a desktop or shelf, simply complete the following steps
:
Step 1
:
Attach the rubber feet to the recessed areas on the bottom of the PoE Switch.
Step 2
: Place the PoE Switch on the desktop or shelf near an AC power source.
Step 3
: Keep enough ventilation space between the PoE Switch and the surrounding
objects.
Step 4
: Connect the PoE Switch to network 802.3at/802.3af powered device(PD) and
switch
Step 5
: Supply Power to the PoE Switch
❖
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and specification of cable match
the requirement before cable laying;
2. It is needed to check the cable is damaged or not, factory records and quality
assurance booklet before cable laying;
3. The required cable specification, quantity, direction and laying position need to
match construction requirements, and cable length depends on actual position;
4. All the cable cannot have break-down and terminal in the middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond the groove in case of
holding back the inlet and outlet holes. Cables should be banded and fixed when
they are out of the groove;
7. User cable should be separated from the power lines. Cables, power lines and
grounding lines cannot be overlapped and mixed when they are in the same
groove road. When cable is too long, it cannot hold down other cable, but structure
in the middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible. Swerving radius cannot be
too small (small swerving causes terrible loss of link). Its banding should be
moderate, not too tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides of the cable for
maintaining.