FIBERROAD FR-5A3010P User Manual Download Page 3

Optical Fiber Port

SFP Transceiver Module 

You can select different SFP modules as required (Please refer to our SFP selection list for 

the appropriate module). To insert/remove the SFP, the procedures are as follow: 

1. On the side panel, insert the SFP module into the SFP port until it is securely locked. 

2. Connect the optical fiber (1/2 core) to the LC connector(s) of the SFP. 

3. To remove the SFP module, press down the lock of the LC connector of the optical fiber 

to pull out the fiber cable. 

4. Pull down the SFP lever and hold its position. Pull out the SFP module from the SFP port. 

Notes: If you make your own cable, we suggest 

labeling the two sides of the same line with the same 

letter (A-to-A and B-to-B, shown as below, or A1-to-A2 

and B1-to-B2).

PoE & Power Supply

User Manual

Item

Specification

PoE Port

Port 1 to 8 IEEE802.3af/at @PoE

Power Supply Pin

Default: 1/2(+), 3/6(-),Optional:4/5, 7/8(-)

Max Power Per Port

30W; IEEE802.3af/at

Total PWR / Input Voltage

125W(DC52V) @ 15.4W 

240W(DC52V) @ 30W

Power Consumption

Standby

4W

Full load

[email protected] 

Full load

250W@30W

Power Inputs

1

Power Supply

External power adapter with AC100 

240V 50-60Hz input

52VDC 5A output@30W per port

52VDC 2A [email protected] per port

AC Plug Types

© 2022 Fiberroad Technology Co., Ltd All right reserved

Page 3 of 11

Connector

Multimode Fiber

Sigle-mode Fiber

1000Base-

SX(850nm

Bandwidth MHZ-KM

Distance

Bandwidth MHZ-

KM

Distance

260

220m

400

500m

200

275m

500

550m

1000Base-LX 

(1310nm/1550nm

Single-mode Fiber 9/125um:2km

Single-mode Transceiver 1310nm: 10/20km

Single-mode Transceiver 1550nm: 40-120km

Summary of Contents for FR-5A3010P

Page 1: ......

Page 2: ...ut should not be able to connect to each other Using this also improves network security 3 When AI QoS is enabled on the 8 port models Port 1 4 will prioritise Video and VoIP traffic flows over others...

Page 3: ...e letter A to A and B to B shown as below or A1 to A2 and B1 to B2 PoE Power Supply User Manual Item Specification PoE Port Port 1 to 8 IEEE802 3af at PoE Power Supply Pin Default 1 2 3 6 Optional 4 5...

Page 4: ...s 1000Base T RJ45 Connector Pin Assignment Pin MDI Signal Definition MDIX Signal Definition 1 BI_DA BI_DB BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_D...

Page 5: ...he data transmission and the cable should be safe The Power over Ethernet system works under the standardization of the Institute of Electrical and Electronics Engineers IEEE 802 3 committee Generally...

Page 6: ...wer to the PoE Switch Wiring Requirements Cable laying need to meet the following requirements 1 It is needed to check whether the type quantity and specification of cable match the requirement before...

Page 7: ...h Powered Device PD in watts Allow for the maximum power and upper end of PD classification Any unspecified devices should be assumed Class 0 For example an IEEE802 3af Class 0 device may consume 9 wa...

Page 8: ...ower supplies Take this harsh scenario for instance A switch and its power supply will be stored in a metal enclosure exposed to direct sun at a site in the northeastern United States In winter the te...

Page 9: ...Full Half Duplex Mode Auto MDI MDI X Connection Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X and 100BaseFX IEEE 802 3ab for 1000BaseT X IEEE 802 3z for 1000BaseSX LX LHX ZX IEEE 802 3x...

Page 10: ...y 5 90 non condensing Storage Temperature 20 70 4 to 158 MTBF 100 819 Hours MTBF Standard Telcordia SR 332 GB 25 Cooling Fanless Passive Cooling Noise Level 0 dBA Certification Warranty Lightning Prot...

Page 11: ...ent Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct t...

Reviews: