FiberPatrol Site Planning & Installation Guide
Page 121
b
Specifications
FiberPatrol control room equipment
Sensor unit part number
•
FP1150xx - up to xx km of cut-immune fence detection
- up to 2 X xx km of non cut-immune fence detection
•
xx variants: 01, 02, 03, 04, 05, 09, 12, 16, 20, 25
Power
•
2 separate AC circuits, 100 - 240 V, 50/60 Hz
3rd circuit required for optional keyboard/monitor/mouse (if
applicable)
•
200 W max. (not including optional keyboard/monitor/mouse)
Mounting
•
EIA-19 in equipment rack with 51 cm (20 in.) mount depth, 5 cm
(2 in.) front space and 15 cm (6 in.) rear space
•
6 RU contiguous rack space, min. 30 cm (12 in.) above floor
4 RU - sensor unit 17.8 cm (7 in.)
1 RU - fiber connection module 4.5 cm (1.75 in.)
1 RU - keyboard/monitor/mouse 4.5 cm (1.75 in.)
Environmental
•
temperature: 0 to 50º C (32 to 122º F)
•
humidity: 20 to 80% non-condensing
Weight
•
sensor unit: 23 kg (51 lb)
•
fiber connection module: 5 kg (11 lb)
•
keyboard/monitor/mouse: 10.5 kg (23 lb)
Alarm reporting
Target resolution
•
45 m (150 ft.) for simultaneous alarms - simultaneous alarms within
45 m may be reported as one alarm; simultaneous alarms separated
by more than 45 m will be reported as individual alarms
location accuracy
•
4 m (13 ft.) in a quiet environment
Virtual alarm zones (software
configured)
•
1440 distinct alarm zones per sensor unit
Cable cut
•
reported and located to within 30 m (98 ft.)
Fib
e
rPatrol sensor cable
Sensor cable part number
•
standard cable FPSP04XX (XX = no. of fibers: 12, 24, 36, 48)
•
armored cable FPSP0624 (24 fibers)
Max. length per reel
•
FP1150 Series approximately 12 km (7.5 mi)
Fiber count
•
optional number of fibers: 12, 24, 36, 48 (2 required as sensor fibers,
remaining dark fibers available for perimeter applications)
Fiber type/wavelength
•
single-mode; 1550 nm
Bend radius (smallest
allowable)
•
dynamic (during installation) - 220 mm (8.66 in.)
•
static (during operation) - 110 mm (4.33 in.)
Tensile rating
•
during installation - 2700 N (600 lbf)
Outside diameter/weight
•
11.5 mm (0.45 in.) maximum; 75 kg/km (50 lb/kft)
Optical power loss
•
max. allowable loss for sensor cable - 0.3 dB/km
•
max. cable attenuation - 0.25 dB/km @ 1550 nm
•
max. loss per event (e.g., fusion splice) 0.1 dB