![Fiberlink FL-117 User Manual Download Page 24](http://html1.mh-extra.com/html/fiberlink/fl-117/fl-117_user-manual_2286736024.webp)
21
C
.
Fiber preparation
1. Put the tube over one end of the fiber.
2. Use fiber stripping pliers to strip fiber coating layer, the length of which
is 30-40 mm. Use gauze dipping with alcohol or wadding to wrap the
fiber, and then clean the bare part.
3. Use a fiber cleaver to cut the fiber
Bare fiber length is 16 mm around.
4. Put the finished fiber in the Fusion Splicer. Cross-section of fiber can not
touch other things.
D
.
Cover the wind protector, then the fiber fusion automatically starts and
the splicing loss is displayed.
E
.
Reinforce the fusion point.
1.
Transfer fiber with protection sleeve from V-grooves to tube heater;
2.
Make sure the splice point is located at the center of the protection sleeve.
Put the tube at the center of the heater.
3.
Press
to start tube heating. The buzzer beeps and the HEAT LED
turn off when tube heating is completed.
4. Remove the tube from the heater when the heater is cool. The whole
process of Fusion Operation is completed.
F
.
Repeat Step II, III, IV to continue splicing.