![Fiberlink FL-117 User Manual Download Page 19](http://html1.mh-extra.com/html/fiberlink/fl-117/fl-117_user-manual_2286736019.webp)
16
after 1,000 arc discharges. When the number of arc discharges reaches a count
of 1,000, a message prompting to replace the electrodes is displayed
immediately after turning on the power. Using the electrodes without a
replacement will result in greater splice loss and reduced splice strength.
Replace Electrodes
<1> Press
button on the operator panel until the LED indicator turn from
red to green, release the button
, now the machine is turned off.
<2> Remove the old electrodes and Method for tearing:
a. Loosen screw located on electrode cover.
b. Take electrode out of electrode cover.
(Electrode is fixed in the electrode cover)
<3> Clean the new electrodes with alcohol-impregnated clean gauze or lint-free
tissue and install them in the splicer.
<4> Place the electrode cover and tighten screw
Do not pull out night light wiring when replacing electrode.
The tightening of the screw should not exceed the strength of fingers.