![FIBER FOX MINI 4R User Manual Download Page 31](http://html1.mh-extra.com/html/fiber-fox/mini-4r/mini-4r_user-manual_2286587031.webp)
7.7 Electrode setting
7.8 Software upgrading
30
30
Set the warning of electrode use, Fiber Fox recommend that after splice 2500
times should replace the electrode to guarantee high quality fusion.
①
Select“electrode setting”and enter into under“Maintenance menu”option.
②
Set electrode use reminding and warning.
①
Select“software upgrading”and enter into under“maintenance menu” op-
tion.
②
C onnect t he U SB flash d isk which carried with t he s oftware upgrading
program to the Mini Hdmi port.
③
P ress confirmation key, t he f usion splicer w ill finish upgrade s oftware
program automatically, after upgrading, the fusion splicer will restart automati-
cally.
Parameter
Description
Electrode use
reminding
Electrode
usewarning
result from electrical machine abrasioncan’t be auto corrected, in addition, the
discharging center position sometimes will move left or right. Under this situation,
the splice position will offset with the discharging center position; now discharging
alignment should be executed to solve the problem.
Note: Discharging alignment will be auto execute just under “AUTO” mode, so
under this mode, you needn’t to do discharging alignment.
Execute “discharging alignment” will change the parameter values of discharg-
ing current strength, this value will be applied in all the splice procedure, but the
discharging current strength value under current splice mode can’t be altered.
Operating steps:
1). After select “discharging current alignment” will display discharging
alignment screen in “splice menu”.
2). Put the prepared fibers to the fusion splicer, and then press SET key to do
discharging alignment.
③
The f usion splicer w ill show t wo p ieces o f numerical a fter discharging
alignment, if the right side value up to 70±10, the fusion splicer will remind you
that operating have been finished, otherwise you need to cut the fiber again to do
discharging alignment until finish the operations.
If the electrode discharging times beyond the electrode use reminding that had been
set, the prompt dialogue box will indicate you to“replace the electrode”when start the
fusion splicer. Fiber Fox suggest setting the parameter to “2500”.
If the electrode discharging times beyond the electrode use warning that had been
set, the prompt dialogue box will indicate you that “must replace the electrode” when
starting up the fusion splicer. Fiber Fox suggest set the parameter to “3500”
Note:
①
Please use standard SM, NZ or MM fiber to do discharging alignment.
②
Please make sure that the fiber is clean, if dust on the surface will influence the
alignment consequence.