FIBARO Walli Operating Manual Download Page 8

8

InstallatIon

4.2: 

Preparing for installation

Prepare wires by removing 11.5-13mm of insulation from their ends.  

You can use groove on the side of the unit to measure the length.

When installing with FIBARO or GIRA cover plates:

1.  Pull out the switch button.
2.  Take off the cover plate.

When installing with Legrand or Schneider cover plates:

1.  Pull out the original switch button.
2.  Take off the original cover plate.
3.  Dismount the original mounting frame.
4.  Snap the new mounting frame*.

* Additional mounting frames are sold separately.

4.3: 

Electrical connection

1.  Switch off the mains voltage (disable the fuse).
2.  Connect with one of the diagrams below:

N

L

Diagram 1: Example con-

nection for double switch 

configuration

N

L

Diagram 2: Example con-

nection for single switch 

configuration

3.  Verify correctness of connection.
4.  Tighten the terminal screws using PH1 screwdriver.

Summary of Contents for Walli

Page 1: ...FIBARO WALLI DOUBLE SWITCH FGWDSEU 221 OPERATING MANUAL EN v1 0...

Page 2: ......

Page 3: ...g the device 10 5 Adding to Z Wave network 11 5 1 Adding manually 11 5 2 Adding using SmartStart 12 6 Removing from Z Wave network 13 7 Operating the device 14 7 1 Controls 14 7 2 Single Double Switch...

Page 4: ...ions Even when the device is turned off voltage may be present at its terminals Any maintenance introducing changes into the configuration of connections or the load must be always performed with disa...

Page 5: ...used with FIBARO Walli covers or other compatible see Parts compatibility on page 39 GIRA System 55 Standard 55 E2 Event Event Clear Legrand C liane Schneider Odace Active power and energy consumption...

Page 6: ...d wires cross section area between 1 5 4 0mm2 stripped 11 5 13mm of insulation Operating temperature 0 35 C Ambient humidity 10 95 RH without condensation Radio protocol Z Wave 500 series chip Radio f...

Page 7: ...with depth no less than 40mm Do not connect devices which are not compliant with the specifi cation or relevant safety standards Do not connect heating devices Do not connect SELV or PELV circuits Ma...

Page 8: ...plates 1 Pull out the original switch button 2 Take off the original cover plate 3 Dismount the original mounting frame 4 Snap the new mounting frame Additional mounting frames are sold separately 4 3...

Page 9: ...eter 13 to 0 When installing with FIBARO cover plates 1 Insert the device with mounting frame into the mounting box and secure with mounting claws and screws 2 Snap the cover plate to the device 3 Sn...

Page 10: ...the new switch button to the device When installing with Schneider cover plates 1 Insert the device with mounting frame into the mounting box and secure with mounting claws and screws 2 Snap the new c...

Page 11: ...Z Wave network manually 1 Power the device 2 Set the main controller in Security non Security Mode add mode see the controller s manual 3 Quickly three times click one of the buttons 4 If you are add...

Page 12: ...support Security S2 see the controller s manual 2 Enter the full DSK string code to your controller If your controller is capable of QR scanning scan the QR code placed on the label on the bottom of t...

Page 13: ...in resetting the device to factory defaults To remove the device from the Z Wave network 1 Power the device 2 Set the main controller into remove mode see the controller s manual 3 Quickly three time...

Page 14: ...must performed before adding it to the Z Wave network To change operating mode before adding to Z Wave network 1 Quickly three times click then press and hold one of the buttons to enter the menu 2 R...

Page 15: ...ON OFF by default Other actions Perform following actions on one of the buttons to 3xClick start learn mode to add remove to from Z Wave network 1 2 3xClick hold release activate scene in the controll...

Page 16: ...switch mode GREEN reset energy consumption memory YELLOW reset to factory defaults 3 Quickly click the button to confirm 7 6 Resetting to factory defaults Reset procedure allows to restore the device...

Page 17: ...e pe riod Consumers of electricity in households are billed by suppli ers on the basis of active power used in given unit of time Most commonly measured in kilowatt hour kWh One kilowatt hour is equal...

Page 18: ...turn the associated de vices on off reflecting button operation uses Basic command class 3rd association group Dimmer is used to change level of as sociated devices reflecting button operation uses Sw...

Page 19: ...Basic Set 2nd group Multilevel Set 3rd group Basic Set 2nd group Multilevel Set 3rd group Multilevel Start Level Change 3rd group Multilevel Stop Level Change 3rd group Single Switch Mode commands sen...

Page 20: ...Set 3rd group Multilevel Start Level Change 3rd group Multilevel Stop Level Change 3rd group Button 2 toggle Basic Set 4th group Multilevel Set 5th group Basic Set 4th group Multilevel Set 5th group...

Page 21: ...e parameter is not relevant for outputs set to pulse mode parameter 150 151 set to 2 Parameter size 1B Default value 1 restores the state Available values 0 remains switched off after restoring power...

Page 22: ...able values 0 function disabled 10 36200 1 0 3620 0W step 0 1W power threshold 10 LED frame power limit Description This parameter determines maximum active power Exceeding it results in the LED frame...

Page 23: ...sumption Parameter size 1B Default value 1 white Available values 0 LED disabled 1 White 2 Red 3 Green 4 Blue 5 Yellow 6 Cyan 7 Magenta 8 colour changes smoothly depending on mea sured power 9 colour...

Page 24: ...evice buttons should control the channels Parameter size 1B Single Switch Mode Default value 1 Available values 1 1st and 2nd button toggle the load 2 1st button turns the load ON 2nd button turns the...

Page 25: ...alue 0 Available values 0 default Q1 1st channel Q2 2nd channel 1 reversed Q1 2nd channel Q2 1st channel 30 Alarm configuration 1st slot Description This parameter determines to which alarm frames and...

Page 26: ...ame blinks green 0x4X LED frame blinks blue 0x8X disable LED frame 0xFX LED frame LAPD signal red white blue 32 Alarm configuration 3rd slot Description This parameter determines to which alarm frames...

Page 27: ...me blinks green 0x4X LED frame blinks blue 0x8X disable LED frame 0xFX LED frame LAPD signal red white blue 34 Alarm configuration 5th slot Description This parameter determines to which alarm frames...

Page 28: ...le and double click are sent Enabling scenes for triple click disables entering the device in learn mode by triple clicking Parameter size 1B Default value 0 no scenes Available values 1 Key pressed 1...

Page 29: ...ue 15 15 Available values 0 reporting on change disabled 1 500 1 500 1 step minimal change 62 Power reports for first channel periodic Description This parameter defines reporting interval for measure...

Page 30: ...value 10 0 1kWh Available values 0 reporting on change disabled 1 500 0 01 5kWh 0 01kWh step minimal change 66 Energy reports for first channel periodic Description This parameter defines reporting in...

Page 31: ...reports disabled 30 32400 30s 9h 1s step time interval 150 First channel operating mode Description This parameter allows to choose operating for the 1st channel Parameter size 1B Default value 0 Ava...

Page 32: ...in Double Switch Mode Description This parameter determines how the device in timed mode reacts to pushing the button for 2nd channel The parameter is relevant only for button tog gles modes paramete...

Page 33: ...nnel Switch ON value sent to 2nd and 3rd association groups Description This parameter defines value sent with Switch ON command to devices associated in 2nd and 3rd association group for manual chang...

Page 34: ...groups Only in Double Switch Mode Description This parameter defines value sent with Switch ON command to devices associated in 4th and 5th association group for manual changes of Endpoint 2 state Par...

Page 35: ...association groups Only in Double Switch Mode Description This parameter defines value sent with Double Click command to devices associated in 4th and 5th association group for manual changes of Endpo...

Page 36: ...0x85 V2 YES COMMAND_CLASS_MULTI_CHANNEL_ASSOCIA TION 0x8E V3 YES COMMAND_CLASS_ASSOCIATION_GRP_INFO 0x59 V2 YES COMMAND_CLASS_TRANSPORT_SERVICE 0x55 V2 COMMAND_CLASS_VERSION 0x86 V2 YES COMMAND_CLASS_...

Page 37: ...URITY_2 0x9F V1 COMMAND_CLASS_SUPERVISION 0x6C V1 COMMAND_CLASS_METER 0x32 V3 YES COMMAND_CLASS_NOTIFICATION 0x71 V8 YES COMMAND_CLASS_PROTECTION 0x75 V2 YES COMMAND_CLASS_APPLICATION_STATUS 0x22 V1 E...

Page 38: ...Command Class allows to prevent local or remote control of the outputs Type State Description Hint Local 0 Unprotected The device is not protected and may be operated normally via the user interface I...

Page 39: ...P 0004 Parts required for GIRA System 55 only with non metalised out er surface Standard 55 E2 Event Event Clear cover plates Required FIBARO parts Name Symbol Walli Double Switch Unit FG WDSEU221 AS...

Page 40: ...her brands and product names referred to herein are trademarks of their respective holders Declaration of conformity Hereby Fibar Group S A declares that the device is in com pliance with the essentia...

Reviews: