![FIBARO Walli Operating Manual Download Page 31](http://html1.mh-extra.com/html/fibaro/walli/walli_operating-manual_2286556031.webp)
31
confIguratIon
68.
Energy reports for second channel – periodic
Only in Double Switch Mode
Description
This parameter defines reporting interval for
measured energy. Periodic reports are indepen-
dent from changes in value (parameter 67).
Parameter size
2B
Default value
3600 (1h)
Available
values
0 – periodic reports disabled
30-32400 (30s-9h, 1s step) – time interval
150.
First channel – operating mode
Description
This parameter allows to choose operating for
the 1st channel .
Parameter size
1B
Default value
0
Available
values
0 – standard operation
1 – delayed OFF
2 – single pulse
151.
Second channel – operating mode
Only in Double Switch Mode
Description
This parameter allows to choose operating for
the 2nd channel.
Parameter size
1B
Default value
0
Available
values
0 – standard operation
1 – delayed OFF
2 – single pulse