20
confIguratIon
Double Switch Mode: commands sent to association groups for
parameter 20 set to 2
1 click
2 click
Hold
Release
Button 1
(ON),
Button 2
(OFF)
Basic Set:
2nd and 4th
group,
Multilevel
Set: 3rd and
5th group
Basic Set:
2nd and 4th
group,
Multilevel
Set: 3rd and
5th group
Multilevel
Start
Change:
3rd and 5th
group
Multilevel
Stop Change:
3rd and 5th
group
Double Switch Mode: commands sent to association groups for
parameter 20 set to 3
1 click
2 click
Hold
Release
Button 1
(toggle)
Basic Set:
2nd group,
Multilevel
Set: 3rd
group
Basic Set:
2nd group,
Multilevel
Set: 3rd
group
Multilevel
Start Level
Change: 3rd
group
Multilevel
Stop Level
Change: 3rd
group
Button 2
(toggle)
Basic Set:
4th group,
Multilevel
Set: 5th
group
Basic Set:
4th group,
Multilevel
Set: 5th
group
Multilevel
Start Level
Change: 5th
group
Multilevel
Stop Level
Change: 5th
group
Double Switch Mode: commands sent to association groups for
parameter 20 set to 4
1 click
2 click
Hold
Release
Button 1
(ON)
Basic Set:
2nd group,
Multilevel
Set: 3rd
group
Basic Set:
4th group,
Multilevel
Set: 5th
group
Multilevel
Start Lev-
el Change:
3rd and 5th
group
Multilevel
Stop Lev-
el Change:
3rd and 5th
group
Button 2
(OFF)
Basic Set:
2nd and 4th
group,
Multilevel
Set: 3rd and
5th group
–
Multilevel
Start Lev-
el Change:
3rd and 5th
group
Multilevel
Stop Lev-
el Change:
3rd and 5th
group