FIBARO WALLI FGWREU-111 Operating Manual Download Page 6

6

specIfIcatIons

3: Specifications

Power supply

110-230V~ 50/60 Hz

Rated load current

4A for motors with compensated power 

factor (inductive loads)
13A for resistive loads

Compatible load types

M

 single-phase AC motors

 resistive loads

Required limit switches

electronic or mechanic

Recommended external 

overcurrent protection

10A type B circuit breaker (EU)  

13A type B circuit breaker (Sweden)

For installation in boxes

Ø = 60mm, depth ≥ 40mm

Recommended wires

cross-section area between 1.5-4.0mm

2

,

stripped 11.5-13mm of insulation

Operating temperature

0–35°C

Ambient humidity

10–95% RH without condensation

Radio protocol

Z-Wave (500 series chip)

Radio frequency

EU: 868.4/868.42/869.85 MHz 

RU: 869.0 MHz

Transmit power

EIRP max. 6dBm

Range

up to 50m outdoors 

up to 40m indoors  

(depending on terrain and building 

structure)

Dimensions  

(Height x Width x Depth)

86 x 86 x 51 mm

Compliance with EU 

directives

RoHS 2011/65/EU 

RED 2014/53/EU

i

Radio frequency of individual device must be same as 

your Z-Wave controller. Check information on the box 

or consult your dealer if you are not sure.

Summary of Contents for WALLI FGWREU-111

Page 1: ...OPERATING MANUAL EN v1 0 FIBARO WALLI ROLLER SHUTTER FGWREU 111...

Page 2: ......

Page 3: ...g the device 10 5 Adding to Z Wave network 11 5 1 Adding manually 11 5 2 Adding using SmartStart 12 6 Removing from Z Wave network 13 7 Calibration 14 8 Operating the device 16 8 1 Controls 16 8 2 But...

Page 4: ...g changes into the configuration of connections or the load must be always performed with disabled fuse To avoid risk of electrical shock do not operate the device with wet or moist hands Do not modif...

Page 5: ...covers or covers from the following prod uct lines see Parts compatibility on page 36 GIRA System 55 Standard 55 E2 Event Event Clear Legrand C liane Schneider Odace Active power and energy metering S...

Page 6: ...mmended wires cross section area between 1 5 4 0mm2 stripped 11 5 13mm of insulation Operating temperature 0 35 C Ambient humidity 10 95 RH without condensation Radio protocol Z Wave 500 series chip R...

Page 7: ...dards and with depth no less than 40mm Do not connect devices which are not compliant with the specifi cation or relevant safety standards Do not connect heating devices Do not connect SELV or PELV ci...

Page 8: ...nstalling with Legrand or Schneider covers 1 Pull out the original switch button 2 Take off the original cover plate 3 Dismount the original mounting frame 4 Snap the new mounting frame Additional mou...

Page 9: ...arameter 13 to 0 When installing with FIBARO covers 1 Insert the device with mounting frame into the mounting box and secure with mounting claws and screws 2 Snap the cover plate to the device 3 Snap...

Page 10: ...the new switch button to the device When installing with Schneider covers 1 Insert the device with mounting frame into the mounting box and secure with mounting claws and screws 2 Snap the new cover p...

Page 11: ...add mode see the controller s manual 3 Quickly three times click one of the buttons 4 If you are adding in Security S2 Authenticated scan the DSK QR code or input the underlined part of the DSK label...

Page 12: ...Security S2 Authenticated add mode see the controller s manual 2 Scan the DSK QR code or input the underlined part of the DSK label on the bottom of the box 3 Power the device 4 Wait for the adding p...

Page 13: ...in resetting the device to factory defaults To remove the device from the Z Wave network 1 Power the device 2 Set the main controller into remove mode see the controller s manual 3 Quickly three time...

Page 14: ...cess completing full cycle up down and up again During the calibration the LED frame blinks white 6 Test whether the positioning works correctly Automatic positioning of standard roller blind using th...

Page 15: ...set to 6000 60 seconds in parameters 156 and 157 3 Move roller blinds between extreme positions by clicking or switch If roller blind stops before reaching top increase value of pa rameter 156 If rol...

Page 16: ...ate slats rotation up Hold initiate slats rotation down Release to stop the movement Other actions Perform following actions on one of the buttons to 3xClick start learn mode to add remove to from Z W...

Page 17: ...ticated Blinking red entering the menu not added to a Z Wave network White start calibration Green reset energy consumption memory Magenta start range test Yellow reset to factory defaults 8 4 Menu Me...

Page 18: ...etting the device is not the recommended way of removing the device from the Z Wave network Use re set procedure only if the primary controller is missing or inoperable Certain device removal can be a...

Page 19: ...energy consumed by a device through a time pe riod Consumers of electricity in households are billed by suppli ers on the basis of active power used in given unit of time Most commonly measured in ki...

Page 20: ...ugh other modules which will be signalled by visual indicator pulsing yellow Visual indicator glowing green the device communicates with the main controller directly Visual indicator pulsing yellow th...

Page 21: ...us and al lows for assigning single device only main controller by default 2nd association group Roller Shutter is assigned to shutter po sition control UP DOWN uses Switch Multilevel command class 3r...

Page 22: ...22 Configuration Switch Multilevel commands sent to association groups for pa rameter 151 set to 2 Click Hold Release Button 1 and 2 Start Stop Level Change 2nd group Set Level 3rd group...

Page 23: ...in the Advanced Settings of the device Available parameters 11 LED frame colour when moving Description This parameter defines the LED colour when the motor is running Parameter size 1B Default value...

Page 24: ...rameter allows reversing the operation of the buttons Parameter size 1B Default value 0 Available values 0 default 1st button UP 2nd button DOWN 1 reversed 1st button DOWN 2nd button UP 25 Outputs ori...

Page 25: ...0x4X LED frame blinks blue 0x8X dis able LED frame 0xFX LED frame LAPD signal red white blue 31 Alarm configuration 2nd slot Description This parameter determines to which alarm frames and how the de...

Page 26: ...ame blinks green 0x4X LED frame blinks blue 0x8X dis able LED frame 0xFX LED frame LAPD signal red white blue 33 Alarm configuration 4th slot Description This parameter determines to which alarm frame...

Page 27: ...tion Status 3B Event State Parameters 4B LSB action 0x00 no action 0xX1 open 0xX2 close 0x0X no action on LED frame 0x1X LED frame blinks red 0x2X LED frame blinks green 0x4X LED frame blinks blue 0x8...

Page 28: ...ption This parameter determines which actions result in sending scene IDs assigned to them Values can be combined e g 1 2 3 means that scenes for single and double click are sent Enabling scenes for t...

Page 29: ...lue parameter 61 Parameter size 2B Default value 3600 1h Available values 0 periodic reports disabled 30 32400 30s 9h 1s step time interval 65 Energy reports on change Description This parameter defin...

Page 30: ...parameter allows adjusting operation ac cording to the connected device Parameter size 1B Default value 1 Available values 1 roller blind with positioning 2 Venetian blind with positioning 5 roller b...

Page 31: ...e limit switch is reached 2 slats return to previously set position in case of the main controller operation momen tary switch operation when the limit switch is reached or after receiving the Switch...

Page 32: ...set manually Parameter size 4B Default value 6000 60 seconds Available values 1 65535 0 01 655 35 seconds 157 Time of down movement Description This parameter determines the time needed for roller bli...

Page 33: ...and Class Version Secure COMMAND_CLASS_ZWAVEPLUS_INFO 0x5E V2 COMMAND_CLASS_SWITCH_MULTILEVEL 0x26 V4 YES COMMAND_CLASS_ASSOCIATION 0x85 V2 YES COMMAND_CLASS_MULTI_CHANNEL_ASSOCIA TION 0x8E V3 YES COM...

Page 34: ...ES COMMAND_CLASS_MULTI_CHANNEL_ASSOCIA TION 0x8E V3 YES COMMAND_CLASS_ASSOCIATION_GRP_INFO 0x59 V2 YES COMMAND_CLASS_SECURITY 0x98 V1 COMMAND_CLASS_SECURITY_2 0x9F V1 COMMAND_CLASS_SUPERVISION 0x6C V1...

Page 35: ...t Local 0 Unprotected The device is not protected and may be operated normally via the user interface Buttons connect ed with outputs Local 2 No operation possible button can not change relay state an...

Page 36: ...le Cover Plate FG Wx PP 0004 Parts required for GIRA System 55 only with non metalised out er surface Standard 55 E2 Event Event Clear covers Required FIBARO parts Name Symbol Walli Roller Shutter Uni...

Page 37: ...her brands and product names referred to herein are trademarks of their respective holders Declaration of conformity Hereby Fibar Group S A declares that the device is in com pliance with the essentia...

Reviews: