confIguratIon
150.
Force calibration
Description
By setting this parameter to 2 the device enters
the calibration mode. The parameter relevant
only if the device is set to work in positioning
mode (parameter 151 set to 1 or 2).
Parameter size
1B
Default value
0
Available
values
0 - device is not calibrated
1 - device is calibrated
2 - force device calibration
151.
Operating mode
Description
This parameter allows adjusting operation ac-
cording to the connected device.
Parameter size
1B
Default value
1
Available
values
1 – roller blind (with positioning)
2 – Venetian blind (with positioning)
5 – roller blind with built-in driver
6 – roller blind with built-in driver (impulse)
152.
Venetian blind – time of full turn of the slats
Description
For Venetian blinds (parameter 151 set to 2) the
parameter determines time of full turn cycle of
the slats.
The parameter is irrelevant for other modes.
Parameter size
4B
Default value
150 (1.5 seconds)
Available
values
0-65535 (0 - 655.35s, every 0.01s) - time of turn