9.4.3
Battery monitor
The battery monitor in the transformer/rectifier monitors the voltage in the
living area battery.
If the battery voltage falls below 10.5 V, the battery monitor in the transformer/
rectifier switches off all the 12 V appliances.
Measures:
Switch off all electrical appliances that are not absolutely essential at the
corresponding switch.
If necessary, use the 12 V main switch to switch the 12 V power supply
back on for a short while. This is only possible, however, when the battery
voltage is above 11 V. If the voltage is below this level, the 12 V power
supply cannot be switched on again until the living area battery has been
recharged.
9.4.4
Charging the battery
When the vehicle engine is running, a relay in the transformer/rectifier alter-
nator switches on the living area battery and the starter battery together and
recharges them with the vehicle generator. When the vehicle engine is
switched off, the batteries are automatically disconnected from one another
again by the transformer/rectifier. This prevents the starter battery from being
run down by electrical appliances in the living area. The starting capability of
the vehicle is thus preserved. The terminal voltage of the living area battery or
the starter battery can be read on the panel.
If the vehicle is connected to the 240 V power supply via the CEE socket
outlet, the living area battery and the starter battery are charged by the charger
module on the transformer/rectifier. The starter battery is only charged with a
float charge. The charging current is adapted to suit the charging condition of
the battery. This ensures that it is not possible to overload the battery.
To make use of the maximum output from the charger module on the trans-
former/rectifier, switch off all electrical appliances during charging.
Z
You must fully recharge a discharged living area battery as soon as
possible.
Summary of Contents for Capron A361
Page 4: ...Contents 4 Capron 04 17 CAP 0017 01EN ...
Page 6: ...6 Capron 04 17 CAP 0017 01EN Warranty 1 ...
Page 10: ...10 Capron 04 17 CAP 0017 01EN Introduction 2 ...
Page 32: ...32 Capron 04 17 CAP 0017 01EN Before the journey 4 ...
Page 72: ...72 Capron 04 17 CAP 0017 01EN Gas system 8 ...
Page 152: ...152 Capron 04 17 CAP 0017 01EN Helpful notes 16 ...