141
Capron - 04-17 - CAP-0017-01
EN
Troubleshooting
15
15.4
Gas system
Starter battery is
discharged in 12 V
operation
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
Battery cut-off switch on
the transformer/rectifier is
switched off
Set battery cut-off switch
to on
No voltage is supplied by
the living area battery
Living area battery is
discharged
Charge living area
battery immediately
Z
Total discharge
damages the
battery.
If the vehicle is to be laid
up for a long period, fully
charge the living area
battery beforehand
X
In case of a defect of the gas system (gas odour, high gas consumption)
there is danger of explosion! Close regulator tap on the gas bottle imme-
diately. Open doors and windows and ventilate well.
X
If the gas system is defective: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.). Check
the tightness of gas-conducting parts and lines with leakage search
spray. Do not check with an open flame.
X
Have the defective gas system repaired by an authorised specialist
workshop.
Fault
Cause
Remedy
No gas
Gas bottle is empty
Change gas bottle
Gas isolator tap closed
Open the gas isolator tap
Regulator tap on the gas
bottle is closed
Open regulator tap on
the gas bottle
External temperature is
too low (-42 °C for
propane gas, 0 °C for
butane gas)
Wait for higher external
temperatures
Built-in appliance is
defective
Contact customer service
Fault
Cause
Remedy
Summary of Contents for Capron A361
Page 4: ...Contents 4 Capron 04 17 CAP 0017 01EN ...
Page 6: ...6 Capron 04 17 CAP 0017 01EN Warranty 1 ...
Page 10: ...10 Capron 04 17 CAP 0017 01EN Introduction 2 ...
Page 32: ...32 Capron 04 17 CAP 0017 01EN Before the journey 4 ...
Page 72: ...72 Capron 04 17 CAP 0017 01EN Gas system 8 ...
Page 152: ...152 Capron 04 17 CAP 0017 01EN Helpful notes 16 ...