background image

MTP_

Data: 13/01/16

file: MTP_ing.doc

pag 6/5

MTP transducer specifications

Power supply

10-25 VDC±20%, max 50mA,
or 5VDC±5% max 100 mA

Signals output

2 quadrature channels,
reference pulse each 5mm

Output

push-pull max 20mA, short-circuit protected
or TTL line driver 5V RS422  (to specify)

Resolution

max 0,01 mm (x4 count)

Measure Accuracy

0,1 mm/m

Maximum speed

3 m/s

Electric connection

cable output 

φ

5 standard length 2m suitable for movable wiring

Maximum distance transducer/band

2 mm

Transducer dimensions

30 x 25 x 10 mm

Pretection degree

IP65

Housing

alluminium

Working temperature

÷

 50°C

Electromagnetic compatibility

2014/30/EU

RoHS

2011/65/EU

Magnetic strip characteristics P50

Length

on request, max 25m

Width

10 mm

Thickness

1,7 mm

Linear thermal expansion coefficient

11 ppm/K

Working temperature

-10 

÷

 65°C

Magnetic ring characteristics DM30 - DM50

Ring external diameter

DM30: Ø30,9 

DM50: Ø48,7

Mounting hole

DM30: Ø14 

DM50: Ø20 (or Ø25)

Resolution with MTP_ transducer

DM30: 2500 pulse/rev 

DM50: 3750 pulse/rev

Max rotation speed with MTP_ transducer

1500 RPM

Summary of Contents for P50

Page 1: ...MTP_ Data 13 01 16 file MTP_ing doc pag 1 5 USER S MANUAL AND MAINTENANCE TRANSDUCER MTP_ MAGNETIC STRIP P50 MAGNETIC RING DM_ ...

Page 2: ... humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instrument does not needs a particular maintenance except cleaning ...

Page 3: ...a signal which opportunely amplified and worked out is changed into an incremental position signal for interfacing with displays PLC CNC axes control etc The band consists of a magnetized plastic ferrite strip with alternate magnetic poles of 5 mm pitch carried by a ferromagnetic steel strip Mechanical protection of the plastic ferrite strip is supplied by a nonmagnetic steel strip The capacity to...

Page 4: ...yl alcohol solvents etc The magnetic band has to be sticked holding the plastic ferrite side in the direction of the sensor which means the steel side leaned on the stand surface Fixed the magnetic band to keep off damages due to abrasions or grazes of the plasic ferrite strip is advisable the appliance always biadhesive of the non magnetic protection streep The optimal ambient temperature for sti...

Page 5: ... connecetd Output signals The measure transducer turns the shifting compared to the magnetic band in digital signals with two squaring channels A B very similar to the signals produced by incremental encoders or optical lines Every 5 mm you have a reference impulse Z which can be used as the zero setting signal of the quota Pay attention if the reference signal Z isn t used it has to be isolate el...

Page 6: ...r movable wiring Maximum distance transducer band 2 mm Transducer dimensions 30 x 25 x 10 mm Pretection degree IP65 Housing alluminium Working temperature 0 50 C Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Magnetic strip characteristics P50 Length on request max 25m Width 10 mm Thickness 1 7 mm Linear thermal expansion coefficient 11 ppm K Working temperature 10 65 C Magnetic ring cha...