Manual purpose

This manual has been designed by the Manufacturer to provide the necessary information regarding the
instrument to those who are authorized to carry out safely its installation, maintenance, dismantling and disposal.
All the necessary information for the buyers and planners can be found in the “Sales catalogue”.
Besides than adopting good technical construction methods, the information should be read carefull yand strictly
applied.Inobservance of this information could cause risks for the health and safety of people and economical
damage. This infor-mation, provided by the Manufacturer in the original language(Italian) is also available in other
languages to satisfy legislative and/or commercial needs.
This manual must be kept in a good condition by a responsible person in an ideal place so that it is always
available for consultation. In case of loss or deteriorioraation of the manual, a replacement should be requested
directly from the manu-facturer quoting the manual’s code.
This manual reflects the state of skill of the instrument at the time of input on the market: however the
manufacturer reserves the right to make changes , add or improve the manual without giving any reason to hold
the present manual inade-quate.

Identification of the equipment

The identification plate represented is applied to the instrument. To find the
identification code of the instrument, consult the sales catalogue.

Environmental conditions

Temperature setting: min. 0°C, max. + 50°C.
It is forbidden to use the instrument other than its specific use and in potentially explosive conditions or where anti-
explosive elements are used.

Storage

Here below are some references to be followed for the storage of the instrument
Avoid environments with excessive humidity and those exposed to bad weather (avoid open areas). Avoid putting
the instrument directly on the ground. Store the instrument in its original packing.

Conformity declaration and EC marking

The instrument answers to the following Communitarian Directives:
2014/30/EU Electromagnetic compatibility, 2014/35/EU Low voltage, 2011/65/EU RoHS.

Maintenance

Reparations should be done only and exclusively at the FIAMA technical assistance centre.
Turn off the power before touching the internal parts. Clean the external plastic parts using a soft, damp cloth with
ethylic alcohol or water.
Do not use hydrocarbon solvents (petrols, diluants): using these products could affect the proper mechanical
functioning of the instrument.

Calibrations and tests

It is advisable to calibrate the instrument periodically, once every working year. To do the calibration , follow the
calibration procedure indicated in the present manual .
For any kind of technical assistance request, contact the sales department of the Manufacturer directly indicating
the information given on the identification plate, the number of hours used and the type of defect.

Manufacturer’s responsibility

The manufacturer declines any responsibility in case of :
• Using the instrument contrary to the national safety and accident-prevention laws.
• Wrong installation, inobservnace or wrong procedures of the instructions provided in the present manual.
• Defective electrical power supply.
• Modifications or tamperings.
• Operations carried out by untrained or unqualified personnel.
The safety of the instrument also depends on the strict observance of the procedures indicated in the manual:
always operate the instument in its functioning capacity and carry out a careful routine maintenance.
• All phases of inspection and maintenance should be done by qualified personnel.
• The configurations provided in the manual are the only ones permitted.
• Do not try to use them anyway contrary to the indications provided.
• The instructions in this manual do not substitute but accomplish the obligations of the current legislation
regarding the safety laws.

Summary of Contents for F1X5 RS

Page 1: ...Display F1X5_RS Data 13 01 16 file F1X5_RS_ing doc Pag 1 12 USER S MANUAL AND MAINTENANCE MICROPROCESSOR DISPLAY F1X5_RS WITH MODBUS RTU SERIAL OUTPUT RS232 RS485 ...

Page 2: ...d weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2014 35 EU Low voltage 2011 65 EU RoHS Maintenance Reparations should be done only and exclusively at the FIAMA technical assistance...

Page 3: ...upply Transducer Terminal Block Serial Output M2 M1 7 8 9 10 Installation Before installing the instrument read the following warnings a Connect the instrument strictly following the instructions of the manual b Carry out the connections using the correct wires within the limits of the tension and power supply as indicated in the technical data c The instrument does not have an ON OFF switch hence...

Page 4: ...etween neutral and earth 1V and the resistance 6 Ohm Connections entries and exits a Physically separate the entry wires from those of the power supply the exits and the power connections use twined and shielded wires with the display connected to the earth only at one point b Connect the exits of adjustments alarms meters electrovalves motors ventilators etc assembling units RC resistance and con...

Page 5: ...ue N B If you input a false password the instrument will immediately leave the programming phase Press RESET ENTER and modify the constant value by means of the digits Press RESET ENTER again to confirm your choice Press to start working with other constants or Press to leave the programming section The constants which have to be programmed and can be run over by the digit are the following ones T...

Page 6: ...ioned values you will get 123 4567 x 100 123456 and IMPULS 10000 The value will be composed by 6 numerals instead of 4 for every visualization Example 2 If you have a proximity sensor and after 10 impulses you need to see the value 7 pls programme in the following way VISUAL 7 and IMPULS 10 Decimal Numbers This constant shows the decimal point position programme 0 if you have not any decimal numbe...

Page 7: ...al contacts A Increasing count impulses from closed to open phase B Decreasing count impulses from closed to open phase B has to be connected to GND if the sensor is NPN to 12V if the sensor is PNP see connection scheme Debounce Filter for Count Inputs If you use an input coming from a mechanical contact in order to avoid debounce impulses you have to programme this constant 1 In this case you can...

Page 8: ... Open collector or push pull PNP Mono directional or proximity transducer connection Open collector or push pull NPN Mono directional or proximity encoder connection Open collector or push pull PNP GND B A 12V A B GND A B 12V B A GND A Vcc GND A Vcc NB With jumper Decreasing count B GND Without jumper Increasing B GND count NB With jumper Decreasing B 12V count Without any jumper increasing B 12V ...

Page 9: ...c 0 15 30Vdc GND Vcc B GND A A B M1 Bi directional connection to the encoder Line driver differential output Micro RESET PRESET max 60 mA F1X50 F1X52 F1X53 0 F1X51 SERIAL OUTPUT CONNECTION M2 1 2 3 4 5 6 GND SERIAL OUT 7 8 RX RS232 RS RS485 TX RS232 RS RS485 NB only one serial output port RS232 or RS485 is active Please refer to F1X5 model ...

Page 10: ...index end static unsigned char auchCRCHi 0x00 0xC1 0x81 0x40 0x01 0xC0 0x80 0x41 0x01 0xC0 0x80 0x41 0x00 0xC1 0x81 0x40 0x01 0xC0 0x80 0x41 0x00 0xC1 0x81 0x40 0x00 0xC1 0x81 0x40 0x01 0xC0 0x80 0x41 0x01 0xC0 0x80 0x41 0x00 0xC1 0x81 0x40 0x00 0xC1 0x81 0x40 0x01 0xC0 0x80 0x41 0x00 0xC1 0x81 0x40 0x01 0xC0 0x80 0x41 0x01 0xC0 0x80 0x41 0x00 0xC1 0x81 0x40 0x01 0xC0 0x80 0x41 0x00 0xC1 0x81 0x40...

Page 11: ...G OF REGISTERS To write the registers of the instrument the master must send a query composed as follows every element is a byte ADDRESS 0x10 START_REG_HI START_REG_LO N_REG_HI N_REG_LO NBYTE DATA_1_HI DATA_1_LO DATA_2_HI DATA_2_LO CRC_HI CRC_LO NBYTE is the number of the given bytes that follow The instrument replies with the following message ADDRESS 0x10 START_REG_HI START_REG_LO N_REG_HI N_REG...

Page 12: ...x14 2 Operation Register 0x15 2 byte HIGH byte don t care this parameter is expressed in encoder count number then is not multiplied by VISUAL IMPULS correction factor The value read from serial port is equal to the display value only if VISUAL IMPULS 4 Technical Features Power supply 115Vac 230Vac 24Vac 15 30Vdc 10 Line frequency 50 60 Hz Power absorbtion 3 VA Display 99999 999999 Inputs type Opt...

Reviews: