Page 16
Short Manual
ResistTel IP2 / IP152
ExResistTel IP2 / IP154
1.5.1
LAN-Connections
1.5.1.1
Default Version one LAN Connection with a Cable
Screw Cap
The telephone has in the default version one internal LAN-connection with a cable
screw cap. For the connection a LAN cable must be pulled through the cable screw
cap. Inside the phone the female LAN connection from AMP NETCONNECT (TE
Connectivity) has to be pressed on the cable (Refer to chapter 1.4 beginning on page
9). A female LAN cable connector belongs to the as-delivered condition. With the
inside the phone existing little LAN connection cable, the LAN can be connected with
the phone.
The LAN delivery can be available with PoE (Power over Ethernet). Alternatively the
phone can be supplied with power external.
All not used cable feed through have to be closed with sealing plugs.
1.5.1.2
Version one LAN Connection with a Female Housing
Connection
The phone has in this version one LAN-connection with a female LAN connection at
the housing. LAN-cable, used for plug into the telephone ResistTel IP2 / IP152, have
to be adapted with a connector from Phoenix contact (Refer to chapter 1.4 beginning
on page 9), to preserve the IP66 degree of protection. A LAN cable connector
belongs to the as-delivered condition.
The LAN-lead wire has to be connected to the connector in the front. Die LAN lead
wire can to be with PoE (Power over Ethernet). Alternatively the phone can be
supplied with power external.
The second LAN connector of the ResistTel IP2 / IP152 is a blind connector closed
with a protective cap to preserve the IP66 degree of protection
All not used cable feed through have to be closed with sealing plugs.
Caution
You can use PoE (Power over Ethernet) or an external connection to supply the
ResistTel IP2 / IP152 with power.
Don’t use both at the same time, to prevent damage to the equipment.