background image

      DEFINITIONS OF LED Light COLORS 

 

 

 

 

TIMER

 

GREEN LED 

TEMPERATURE 

RED LED 

STATUS 

BLUE LED 

 

 

 

DURING STARTUP 

1 flash-4 hours “ON” 
2 flashes-8 hours “ON” 
3 flashes -24 hours “ON” 

(4 hours is factory set default) 
24 hrs. is useful for hot water service 

DURING STARTUP 

1 flash-170°F/76.7°C 
2 flashes-176°F/80°C 
3 flashes-182°F/83.3°C 
4 flashes =-188°F/86.7°C 

(182°F is factory set default) 

DURING STARTUP 

 
 

(Inactive during startup) 

 
 

AFTER STARTUP 

Steady GREEN when operating 
Blinks GREEN if empty or cold 

AFTER STARTUP 

Steady RED after timeout 
…Or when emptied 

AFTER STARTUP 

BLUE 15 min before timeout: 
then changes to steady RED 

 

INNOTHERM HEATED DISPENSER OPERATION: 

 

STARTUP 

 

INNOTHERM is ready to operate as received.  INNOTHERM must be filled with liquid at least 145°F to operate. 
Always pre-heat INNOTHERM for best results.  Brew at least one half full water only, hold 2-10 min & drain. 
The INNOTHERM heater will hold the contents four hours at 182°F.  At the end of the timer, the heater shuts off. 
INNOTHERM may be user programmed to the settings above.  Programming instructions are on the next page. 

 

 

Turn INNOTHERM ON

 by connecting the magnetic power cord connector to the magnetic power receptacle located 

on the right hand side of the INNOTHERM, between the front stand leg and the rear stand leg. 

  

 Once 

the 

power connection has been made

 INNOTHERM walk through the current programmed settings.   

 

  First INNOTHERM will flash the corresponding number of 

GREEN 

flashes indicating the current setting for 

TIME

 

 (1 flash = 4 hours 

[DEFAULT]

, 2 flashes = 8 hours, 3 flashes = 24 hours).  There are three 

TIME

 settings. 

 

 (After a 2 second pause)  

 

  Second: INNOTHERM will flash the corresponding number of 

RED

 flashes indicating the current setting for 

TEMP

  

(1 flash = 170° F setpoint, 2 flashes = 176° F, 3 flashes = 182° F 

[DEFAULT]

, 4 flashes = 188° F setpoint).   

There are four 

TEMP

 settings. 

 

INNOTHERM HEATED DISPENSER OPERATION: 

 

OPERATION 

 

  Pre-heat cold INNOTHERM for best results.  Brew ½ full water only, hold 2-10 min & drain   

 

 Once 

the 

TIME

 and 

TEMP

 setting indications are completed, the LED located in the front lower right-hand side will 

begin 

flashing GREEN

.  This indicates that INNOTHERM is connected to power and is in the Idle mode 

 

 To 

activate the INNOTHERM  heater,

 you must pour in hot liquid at 

145° F temperature (or hotter).

   

When the heater is engaged the LED will change over to 

continuous GREEN

  

LED  will remain 

continuous GREEN

 throughout the

 

cycle

 TIME

 setting (Of 4 hours, 8 hours or 24 hours). 

 

 At 

15 minutes remaining 

in the 

TIME

 cycle

 

the LED will change from 

continuous GREEN

 to 

continuous BLUE

 

This is a notification to the operator that the end of the 

TIMED HEATING 

cycle is near. 

 At 

the 

end of the heating cycle TIME 

or when 

INNOTHERM is EMPTY

, the LED changes to 

continuous RED

 

This indicates INNOTHERM timer has shut off the heater.   

 

Attaching the Magnetic Connector acts as the ON/OFF switch

 

User programming interface 
with indicating LED lights  
 
Simple Magnetic Connector 
…Bring together and “click

” 