background image

Freshness

 

Timer®

 

FETCO

 

indicator

 

funnel

 

Volume

 

Indicator

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Maintaining

  

The

 

L4

 

Funnel

 

 
 
 
 
 
 
 
 
 

 

Quad

 

icons,

 

each

 

divided

 

into

 

quarter

 

hours

 

segments—The

 

four

 

icons

 

represent

 

a

 

time

 

range

 

of

 

four

 

hours

 

Blank

 

indicator

 

funnel

 

display

 

is

 

shown,

 

dispenser

 

is

 

“Ready”

 

for

 

brewing

 

Lower

 

“VEE”+

 

four

 

upper

 

bars

 

represent

 

20%

 

increments

 

of

 

fill

 

level

 

of

 

the

 

dispenser

 

 

BLANK:

 

Empty—Ready

  

To

 

Brew

 

”READY”

 

TO

 

BREW”

 

1

15…minute

 

time

 

range

 

 

Fifth

 

Level

FULL

 

16

30…minute

 

time

 

range

 

 

Fourth

 

Level=80%filled

 

…Some

 

displays

 

are

 

omitted

 

for

 

clarity

 

 

 

Slowly

 

pulsing

 

display:

 

 

…more

  

than

 

4

 

hours

 

 

…Active

 

On

 

&

 

Off…

 

Third

 

Level=

 

60%

 

filled

 

 

 

Second

 

Level=40%

 

filled

 

First

 

Level=20%

 

filled

 

DISPENSER

 

EMPTY

 

 

Accessing

 

Dispenser

 

Parts

 

 

REMOVING THE DRIP TRAY      REMOVING THE FAUCET GUARD       REMOVING THE FAUCET 

 

 

 

1) Unscrew knob approximately 

 

 

 

four turns  

   2) 

Slide 

faucet 

guard 

out.

 

 
 
 

 

 

 

 

 

 

 

 

 

 

               

knob

 

Slide drip tray out 

 

 

       

latch release                                              Press faucet 

 

 

 

 

 

                release latch up

.

 

 
 
 
 
 
 
 

 

 Rotate faucet 180° 

 

 and pull it out 

 

 

Unscrew faucet upper 

Reverse procedure to re-install 

 

      assembly to clean or   

faucet.  Press release latch down 

 

 

 replace seat cup 

to lock faucet into place--!!Click!!

 

 

 

IMPORTANT

 

SAFEGUARDS

 

To

 

prevent

 

overflows,

 

make

 

sure

 

the

 

dispenser

 

is

 

completely

 

empty

 

before

 

brewing.

 

Always

 

remove

 

the

 

funnel

 

for

 

manual

 

filling

 

of

 

the

 

dispenser.

 

Use

 

only

 

the

 

large

 

handle

 

to

 

lift

 

or

 

carry

 

the

 

dispenser.

  

NEVER

 

use

 

the

 

small

 

funnel

 

bail

 

to

 

lift

 

or

 

carry

 

the

 

dispenser

 

Do

 

not

 

use

 

the

 

faucet

 

guard

 

to

 

pull

 

or

 

lift

 

the

 

dispenser.

 

Do

 

not

 

use

 

bleach

 

or

 

cleaners

 

containing

 

chlorides.

 

Do

 

not

 

use

 

solvent

 

based

 

cleaner

 

or

 

polish

 

on

 

this

 

equipment

 

Never

 

use

 

a

 

cleaner

 

on

 

any

 

food

 

equipment

 

that

 

contains

 

the

 

solvent

 

diethylene

 ‐ 

glycol

 

butyl

 

ether

 

(DGBE)

 

.

 

Use

 

only

 

non

metallic

 

brushes

 

and

 

non

abrasive

 

cleaning

 

pads.

 

Do

 

not

 

submerge

 

the

 

brew

 

funnel

 

CLEANING

 

AND

 

MAINTENANCE

 

Detailed

 

instructions

 

are

 

available

 

on

 

our

 

web

 

site,

 

www.fetco.com.

 

Daily:

 

Important

 

Notice:

 

To

 

maintain

 

proper

 

operation

 

of

 

the

 

funnel

 

display,

 

clean

 

the

 

funnel

 

stem

 

daily

 

under

 

running

 

water

 

with

 

detergent

 

and

 

a

 

non

abrasive

 

sponge

 

or

 

towel.

  

DO

 

NOT

 

SUBMERGE

 

FUNNEL

 

OR

 

DISPENSER

 

Use

 

any

 

commercial

 

beverage

 

urn

 

cleaner

 

to

 

clean

 

the

 

inside

 

of

 

the

 

dispenser.

 

Follow

 

the

 

cleaner

 

manufacturer’s

 

instructions.

   

Thoroughly

 

rinse

 

the

 

dispenser

 

after

 

cleaning.

 

Wash

 

the

 

drip

 

tray

 

and

 

other

 

plastic

 

parts

 

with

 

dish

 

detergent.

 

Avoid

 

abrasives.

 

To

 

sanitize

 

the

 

dispenser

 

before

 

filling,

 

brew

 

a

 

batch

 

of

 

water

 

only

 

(no

 

coffee)

 

into

 

the

 

dispenser

 

and

 

allow

 

it

 

to

 

rest

 

for

 

10

 

minutes.

 

Weekly,

 

or

 

as

 

needed:

 

Remove

 

the

 

faucet

 

upper

 

assembly

 

and

 

inspect

 

the

 

seat

 

cup

 

for

 

wear.

 

Clean

 

or

 

replace

 

if

 

necessary.

 

 

INNOTHERM

 

1)

 

Fill

 

dispenser

 

with

 

hot

 

liquid

 

to

 

preheat

 

before

 

brewing,

 

empty,

 

and

 

then

 

brew

  

2)

 

Connect

 

magnetic

 

connector

 

of

 

power

 

supply

 

to

 

the

 

heated

 

dispenser

 

3)

 

Plug

 

in

 

power

 

supply

 

to

 

outlet

 

CONNECTING

 

AND

 

DISCONNECTING

 

THE

 

POWER

 

SUPPLY

 

Important

 

Notice:

 

Disconnect

 

power

 

supply

 

module

 

before

 

filling

 

and

 

cleaning.

 

Reconnect

 

power

 

supply

 

for

 

beverage

 

service

 

Heater

 

is

 

activate

 

only

 

when

 

dispenser

 

is

 

filled

 

with

 

liquid

 

warmer

 

than

 

145°F

 

     ‐

Never

 

expose

 

power

 

supply

 

module

 

or

 

wire

 

to

 

moisture

 

Heater

 

does

 

not

 

reset

 

after

 

time

out.

  

Unplug

 

and

 

plug

 

in

 

to

 

reset

 

timer

 

DO

 

NOT

 

DISSASSEMBLE

 

DISPENSER

NO

 

USER

 

SERVICE

 

PARTS

 

 

 

 
 
 

 

NO DISHWASHER 

 

 

 
 
 

 

NO MICROWAVE 

Clean and dry funnel 

 by hand only

 

FUNNEL 
DISPLAY 

Time is reset when dispenser is 
completely emptied, when funnel is 
removed, or when enough liquid is 
added to increase the volume by at 
least one level

 

TO REMOVE FUNNEL ASSEMBLY 

 

NOTE:  
 NEVER carry dispenser by the bail handle 
-Swing large carrying handle to rear 
-Lift funnel by small bail handle 

 

Important Notice: To maintain proper operation of 
the funnel display, clean the funnel stem daily 
under running water with detergent and sponge,  
or non-abrasive pad or towel.  

 

Do not submerge

 

 

Brew funnel must be removed for manual filling 
of dispenser.

 

 

Removing the funnel resets timer.

 

 

To extend battery life, remove the funnel when 
not in use. 
     (Battery cannot be replaced.)

 

 

TO ACCESS BREW FUNNEL

 

 

Remove both plug and bail handle

 

 

-Snap cover out at OPEN hinge knuckle

 

 

-Squeeze funnel bail inward at knuckles to 
remove

 

USER NOTE FOR HEATED DISPENSER: 

 

INNOTHERM heated beverage dispenser will not raise the 
temperature of the contents inside of it.  INNOTHERM is 
not designed as a cooking appliance-it is designed only to 
keep the heated contents at a selected temperature 

Reviews: