Fetco HWD-2110 TOD User Manual Download Page 7

 

7

Programming and diagnostic screens 

 
To enter Programming and Diagnostics dialog screens 
 
Turn power switch on lower back of unit “OFF” 
Turn power switch “ON” and when first screen is displayed touch lower (red) pad to activate 
The First Programming screen will display.  Displayed are the default settings programmed into the equipment 
Touch upper “Touch Function Selector” to scroll through the programming lines. 
Touch lower (red) pad to scroll through the screens and active outputs.   
Setting 

as displayed

 will be saved on exit. 

EXIT Programming and Diagnostics dialog by selecting EXIT and touching the lower (red) pad 
 

 

Programming for 
hot water tank  
temperature setting 
(also dispense 
temperature) 
and display units (°C 
or °F) 
 

PROGRAMMED 
Tank Temperature 
and Dispense 
Temperature are 
the same 

Internal tank functions 
Verify probe readings 
for  tank temperature,  
and water level.   
Show status of liquid 
level probes for tank 
water level. 
 
Touch pad verification 
( instructions in 
following section)  

Output functions 
And test points. 

 
Will activate 
selection for 2-3 
seconds. 

Service technician 
error report for fault 
and software 
diagnostics and 
upgrade 

Chart to correct for boiling point for altitude  

in tank water temperature. 

See INPUT Screen

 

Altitude (ft.) 

Suggested 
Setting(°F)

 

Boiling 

point (° F) 

-500 

207 

212.9 

207 

212.0 

500 

207 

211.1 

1000 

205 

210.2 

2000 

204 

208.4 

2500 

203 

207.5 

3000 

200 

206.6 

3500 

197 

205.7 

4000 

195 

204.8 

4500 

194 

203.9 

5000 

194 

203.0 

5500 

193 

202.0 

6000 

192 

201.1 

6500 

191 

200.2 

7000 

190 

199.3 

7500 

188 

198.3 

8000 

187 

197.4 

 

 

 

 

Error Code Screen

 

 

Error codes are cleared by 

selecting the “OTHER “ screen.   

Scroll and press the upper 

control to “Reset Error Codes”.   
 

Press the lower selector to clear.

Error codes 

050 

Shorted temperature probe - tank 

051 

Open temperature probe - tank 

052 

Outlet temperature sensor shorted 

053 

Outlet temperature sensor open 

100 

Initial fill error (not filled in 6 minutes after power up) 

101 

Error on refill  (The tank has not refilled in 1 minutes-  

 

Possibly faulty solenoid or issue with the water line) 

102 

Unwanted fill  (Possibly tank or internal leak) 

103 

Overflow error (float switch activated) 

104 

Lower (longer) liquid level probe fault 

105 

Upper (shorter) liquid level probe fault   

200 

Flat line temperature 

201 

Heater open (heater or triac failure)

 

 

 

Touch pad function test 

 
Tests the Upper and Lower touch pads for proper sensitivity. 
Use after servicing to check functionality of the touch pad  
When selected - the indicator will display the key being touched. 
 
The example to the right shows the UPPER -White key is active. 
 
Touching the LOWER-Red pad will highlight the red key marker 
 
Circuit logic digits may display variable number.  Used for manufacturing

 

000    000   201 

0510 0102 1122 

Summary of Contents for HWD-2110 TOD

Page 1: ...US patents applied for FETCO is a trademark of Food Equipment Technologies Company 2011 Food Equipment Technologies Company November 2011 NOTICE TO INSTALLER Please leave this book with the machine Us...

Page 2: ...ate per hour based on 65 70 F 18 21 C mains water supply temperature at lowest possible electrical supply current Factors affecting temperature accuracy include quantity of hot water dispensed ambient...

Page 3: ...should be installed after the water shutoff valve and in a position to facilitate filter replacement 5 Flush the water supply line and filter before connecting it to the unit 6 Verify that the water l...

Page 4: ...dispensed in succession 6 Unit returns to inactive Enabled Screen if no water is dispensed in 3 seconds 7 Steam and condensation from the water tank is released into the vent whenever the unit is on...

Page 5: ...rvice technician Notice Turn off power to the HWD 2110 before any cleaning procedure including wiping the exterior for appearance reasons Dry the exterior especially the face panel before turning on p...

Page 6: ...wo to three 2 3 seconds The upper white selector pad will light when selected temperature is ready Touch and hold lower red pad to dispense hot water Maximum single dispense is 24ounces 700cc in 15 se...

Page 7: ...Setting F Boiling point F 500 207 212 9 0 207 212 0 500 207 211 1 1000 205 210 2 2000 204 208 4 2500 203 207 5 3000 200 206 6 3500 197 205 7 4000 195 204 8 4500 194 203 9 5000 194 203 0 5500 193 202 0...

Page 8: ...8 HWD 2110 DOMESTIC Wiring diagram...

Page 9: ...9 HWD 2110 EXPORT Wiring diagram...

Page 10: ...240VAC 1 2 1059 00001 00 TRIAC 40A 600V 1 3 1053 00004 00 THERMOSTAT SINGLE SHOT 25A 1 4 1024 00007 00 O RING DASH 344 TANK COVER 1 5 1102 00007 00 TANK COVER ASSEMBLY 1 6 1054 00006 00 FILL SENSOR HW...

Page 11: ...11 Drawing 1109 00033 00 HWD 2110 Service Parts...

Page 12: ...D 2100 1 13 1029 00023 00 FITTING SINGLE BARBED ELBOW 1 4 KYNAR 1 14 1052 00010 00 TERMINAL BLOCK 3 POLE 30 AMP 10 22 AWG 1 15 1057 00043 00 SOLENOID VALVE SINGLE 180 DEG 24VDC 1 16 1058 00020 00 SWIT...

Reviews: