Fetco EXTRACTOR CBS-1131V+ Programming Manual Download Page 6

-After all brew recipes are set press 

STOP

 button to go to–GENERAL “B” 

 

B1 is Tank Temperature 
This controls the brew water temperature and the hot water service faucet 
Toggle buttons A20 and A30 to make changes

   

Then press A10 to advance 

B2 is Brew at Temperature  
Default is YES.  Brew will not start until 
hot water tank temperature is at setpoint. 
If Brew at Temp is set to “NO”-brew will start at any temperature above 
77°C/170°F.  Toggle buttons A20 & A30 to adjust 
Then press A10 to advance 
-Following the PROGRAMMING MENU LAYOUT chart shown on page 2 
Complete your adjustments in the GENERAL –“B” parameter 
- Settings found under BATCH PROGRAM “A” GENERAL “B  include most 
needed for start-up and operation.  
-Always verify the model number (displayed when brewer first powered 
ON).  Model selection is found in E2 
-Always SAVE & EXIT as shown in screen “F” or new settings will be lost. 
Press A10 to advance though the settings to change or check settings  
-then press STOP to continue scrolling across C-E positions  

Tank Temp 

  B1   200F   ±  

First programming position 

“B1”  

Is for hot water tank temperature

 

  Brew @ Temp 
  B2   YES      

-

 

Brew pauses & will start when hot 
water tank temp. is at setpoint

 

Summary of Contents for EXTRACTOR CBS-1131V+

Page 1: ...www fetco com 2008 2018 Food Equipment Technologies Company Part P172 January 2018 FETCO EXTRACTOR and V are trademarks or trade names of Food Equipment Technologies Company CBS 1100V Programming Guid...

Page 2: ...et 0 B4 Temperature F C C4 Keypad Test D4 Test L Brew Valve E4 Clear Errors A16 Drip Delay B5 Volume unit G or L D5 Screen Brightness E5 Reload Defaults A20 Batch ACTIVATE B6 Left Flow Rate E6 Save to...

Page 3: ...1 00 A16 Drip Delay Min Sec 1 30 1 30 B1 Hot Water Tank Temp 200 F 200 F B2 Brew at Set Temperature YES ON YES ON B3 LLC Sensitivity See User Guide LOW LOW B4 Temperature Scale F F B5 Water Volume Sca...

Page 4: ...to enter menus for individual settings under letter NOTE Buttons light up only when they are available to make adjustment Batch Settings Advance through settings The menu topics are numbered A1 A7 B1...

Page 5: ...To hide or deactivate a button toggle the BATCH ACT screen A11 screen sets the total brew volume Note some water is retained in the used coffee grounds Scroll down press button A10 to the next settin...

Page 6: ...o advance Following the PROGRAMMING MENU LAYOUT chart shown on page 2 Complete your adjustments in the GENERAL B parameter Settings found under BATCH PROGRAM A GENERAL B include most needed for start...

Page 7: ...nnot be disabled A10 A40 A1 Brew Volume 3 liters CBS 1130V 1 50 gal CBS 1150V CBS 1130V 0 95 4 75 Liters To switch between gallons and liters go to position B5 CBS 1150V 0 50 2 00 Gallons A2 Brew Time...

Page 8: ...R GUIDE B4 Temperature Scale F Fahrenheit F C NOTE Changing will overwrite user settings B5 Volume Scale L CBS 1130 G CBS 1150 Liters Gallons User adjustable CBS 1130V factory set in liters CBS 1150V...

Page 9: ...Parameters D OUTPUTS settings Position Name and default setting Range Comment D1 Heater Test ON OFF 10 seconds maximum ON time Energizes Heaters For diagnostics service use only D2 Fill Valve Test ON...

Page 10: ...hort circuit in temperature probe Probe failure Replace probe 051 Open temperature probe Bad probe connection or probe failure Check all connections Replace probe if necessary 100 Initial Fill Error I...

Page 11: ...error codes should be after completing the service and factory diagnostics and correcting any brewer faults Clear error codes by cycling the brewer OFF then ON E4 Reset Errors YES NO NOTE Always cont...

Page 12: ...ing turning power OFF then ON All changes made will be discarded and brewer will remain in the existing default settings From any screen Press STOP button until the EXIT F screen appears From the F sc...

Reviews: