  To change recipes                       

Illustration shows each recipe batch position

 

 All recipe programming is made from the “A” screens  
 

TO ACCESS BATCH RECIPES: 

-Enter “A”-

BATCH PRG

 

-Press button “A10” to scroll through the parameters 
Press “STOP” to scroll across the other recipe buttons  
Single brewer has 3 recipes.  Twin brewer has 6 recipes  
-All recipe settings are programmed from the “A” screen.   
Each recipe button may be individually programmed. 
Top recipe buttons (A10&A40) are permanent.  Lower recipe buttons 
(A20, A30&A50, A60 if dual can be hidden.  To hide or deactivate a 
button: toggle the BATCH ACT screen. 

A11 screen sets the total brew volume 

 
Note

:

 

some water is retained in the used coffee grounds

 

-Scroll down (press button A10) to the next setting A12 to set brew time to 
dispense the volume set in A11.

   

Note:

 goes to default setting if set too short for volume entered

 

- Press A10 button continue scrolling down through A13-A15 for all 
recipes. (See user guide for detailed explanation of each parameter) 

 

CBS-1132V+ 

A20

 

 

       

STOP

 

       

STOP

 

 

 

A50

 

A30

 

 

A60

 

 

A10

 

 

A40

 

 

BREW VOLUME 

  A11   3.00 L  ±  

First programming position 
A11 is shown in example 

BREW TIME 

  A12   04:00 ±  

Second programming position 
A12 is shown in this example 

BATCH ACT 

  A20  YES   

Toggle to NO to deactivate 

or hide lower recipes 

Summary of Contents for EXTRACTOR CBS-1131V+

Page 1: ...www fetco com 2008 2018 Food Equipment Technologies Company Part P172 January 2018 FETCO EXTRACTOR and V are trademarks or trade names of Food Equipment Technologies Company CBS 1100V Programming Guid...

Page 2: ...et 0 B4 Temperature F C C4 Keypad Test D4 Test L Brew Valve E4 Clear Errors A16 Drip Delay B5 Volume unit G or L D5 Screen Brightness E5 Reload Defaults A20 Batch ACTIVATE B6 Left Flow Rate E6 Save to...

Page 3: ...1 00 A16 Drip Delay Min Sec 1 30 1 30 B1 Hot Water Tank Temp 200 F 200 F B2 Brew at Set Temperature YES ON YES ON B3 LLC Sensitivity See User Guide LOW LOW B4 Temperature Scale F F B5 Water Volume Sca...

Page 4: ...to enter menus for individual settings under letter NOTE Buttons light up only when they are available to make adjustment Batch Settings Advance through settings The menu topics are numbered A1 A7 B1...

Page 5: ...To hide or deactivate a button toggle the BATCH ACT screen A11 screen sets the total brew volume Note some water is retained in the used coffee grounds Scroll down press button A10 to the next settin...

Page 6: ...o advance Following the PROGRAMMING MENU LAYOUT chart shown on page 2 Complete your adjustments in the GENERAL B parameter Settings found under BATCH PROGRAM A GENERAL B include most needed for start...

Page 7: ...nnot be disabled A10 A40 A1 Brew Volume 3 liters CBS 1130V 1 50 gal CBS 1150V CBS 1130V 0 95 4 75 Liters To switch between gallons and liters go to position B5 CBS 1150V 0 50 2 00 Gallons A2 Brew Time...

Page 8: ...R GUIDE B4 Temperature Scale F Fahrenheit F C NOTE Changing will overwrite user settings B5 Volume Scale L CBS 1130 G CBS 1150 Liters Gallons User adjustable CBS 1130V factory set in liters CBS 1150V...

Page 9: ...Parameters D OUTPUTS settings Position Name and default setting Range Comment D1 Heater Test ON OFF 10 seconds maximum ON time Energizes Heaters For diagnostics service use only D2 Fill Valve Test ON...

Page 10: ...hort circuit in temperature probe Probe failure Replace probe 051 Open temperature probe Bad probe connection or probe failure Check all connections Replace probe if necessary 100 Initial Fill Error I...

Page 11: ...error codes should be after completing the service and factory diagnostics and correcting any brewer faults Clear error codes by cycling the brewer OFF then ON E4 Reset Errors YES NO NOTE Always cont...

Page 12: ...ing turning power OFF then ON All changes made will be discarded and brewer will remain in the existing default settings From any screen Press STOP button until the EXIT F screen appears From the F sc...