background image

Go to fetco.com for the latest versions of all information         

Page 6

                                                   

P167  November  2017 

 

 

 

RECIPE Location map 

 

Viewing and changing settings for the brew 
recipes is from the “A” screens with the controls 
in PROGRAMMING. 
 
The uppermost button positions are permanent 
and will not display programming step A_0.  The 
table above shows in position A20 that a button 
position can be made active or inactive.   
Position A1 does not display this step 

 

DISPLAY

 

 

DISPLAY 

STOP

 

 

BATCH A1

 

(permanent)

 

BATCH A4 

(permanent)

 

BATCH A2

 

BATCH A5 

BATCH A3

 

BATCH A6 

A PROGRAM 

Menu Features: Batch Parameters

 

The settings below are shown for the top batch on a single brewer top left button on a twin brewer. 

See how to access all A menus on the previous page.  Below are the brew settings for default A1 & A2  batches 

POSITION Program 

Items 

Factory set  

Default 

Programming Range  Increments 

Notes 

A11 Batch 

Volume 

1.5 gal 

5.65 liters 

0.50 to 2.00 gal 

1.90 to 7.60L 

0.01G 

0.05L 

Unit software is in liters; 

converts to gallon 

A12 

Brew Time 

4:00 minutes 

2:00 – 12:00 

0.30 

Default total brew time is 

5:30 minutes 

A13 

Prewet Perc. 

0% 

0.00 – 15.0% 

1% 

Percentage of total brew 

volume 

A14

 

Prewet Delay 

 

(Pause after prewet 

completes) 

0% [1:00 Min] 

[0:10 – 5:00] 

1:00 min 

The time between 

prewetting and start of 

brew cycle. 

This feature appears 

ONLY if Prewet >0:00 

A15 

 

This is a 

Safety 

Feature

 

Drip Delay 

1:30 mm:ss 

0:30 – 6:00 Min. 

 

Time that brew basket 

remains locked during final 

drip-out 

Drip delay remains “ON” 

for 1:30 minutes if STOP  

is pressed during brew † 

 

 

 

 

 

A20 

BATCH ACT 

A20  YES 

-

  

         NO   

+

 

YES 

(Active) 

Middle and Bottom 

batches A2,3,5,6 

Batch on 

or off 

Batches may be 

individually enabled, 

rewritten or deactivated  

A21 

Batch Volume  

1.5 gal 

5.65 liters 

0.50 to 2.00 gal 

1.90 to 7.60L 

0.01G 

0.05L 

Unit software is in liters; 

converts to gallon 

A22 

Brew Time  

4:00 minutes 

2:00 – 12:00 

0.30 

Default total brew time is 

5:30 minutes 

A23 

Prewet Perc.  

0% 

0.00 – 15.0% 

1% 

Percentage of total brew 

volume 

A24

 

Prewet Delay  

 
(Pause after prewet 
completes) 

0% [1:00 Min] 

[0:10 – 5:00] 

1:00 min 

The time between 

prewetting and start of 

brew cycle. 

This feature appears 

ONLY if Prewet >0:00 

A25 

 

This is a 

Safety 

Feature

 

Drip Delay  

1:30 mm:ss 

0:30 – 6:00 Min. 

 

Time that brew basket 

remains locked during final 

drip-out 

Drip delay remains “ON” 

for 1:30 minutes if STOP  

is pressed during brew†  

Batch Copy

 Copy From Batch  A71 

A71 1 (1-6) 

 

 

 Copy To Batch? 

A72 

A72.1 (1-6) 

 

 

*Topmost Batch cannot be disabled.     *Topmost Batch LEFT & RIGHT Side cannot be disabled.  
**Middle and bottom batches may be disabled for single and twin brewer (CBS-1151 XV+ and CBS-1152 XV+) 

† DRIP DELAY

 will not activate when STOP is pressed within 5 seconds of starting a brew time

 

A1 

A2 

A3 

Single Side Models 

CBS-1151 V+ 

 
STOP 

A4 

A5 

A6 

Twin Models 

CBS-1152 V+ 

 

 
STOP 

A1 

A2 

A3 

 
STOP 

Summary of Contents for CBS-1150 EXTRACTOR V+

Page 1: ...8 F SAVE EXIT 9 Error Codes 9 Operator Training 10 Cleaning Maintenance 10 Installation Guide 11 Parts Diagrams CBS 1151V 14 Parts Diagrams CBS 1152V 16 CBS 1151V Tank Assembly 18 CBS 1152V Tank Assem...

Page 2: ...e Remove jumper between L2 and L3 and apply power to L3 Specifications and Requirements Water Requirements Coffee Filter Size CBS 1150 XV 20 75 psig 138 517kPa 1 gpm 5 7lpm 15 X 5 standard FETCO F001...

Page 3: ...llon 6 Liter coffee brewers USA and Canada CBS 1152 XV Field Select Electtical With cUL UL and NSF 4 certification Configuration Codes Heater Configuration Voltage Phase Wires Electrical Connection KW...

Page 4: ...ettings for the brewer TO ENTER PROGAMMING 1 Turn brewer OFF from power switch 2 Turn power switch to ON Screen will initialize and then display digital process notifications 3 After iitailization Red...

Page 5: ...ter A2 A5 A3 bottom A3 A6 A1 to A7 B1 0 to B1 7 C1 0 to C1 3 D1 0 to D1 5 E1 0 to E1 8 PROGRAM GENERAL INPUTS OUTPUTS OTHER A_0 Batch Activate A_1 Brew Volume B1 Tank Temp C1 LLC Probe D1 Test L Brew...

Page 6: ...is feature appears ONLY if Prewet 0 00 A15 This is a Safety Feature Drip Delay 1 30 mm ss 0 30 6 00 Min Time that brew basket remains locked during final drip out Drip delay remains ON for 1 30 minute...

Page 7: ...94 7 5500 1676 193 201 5 89 94 2 6000 1829 192 200 6 89 93 6 6500 1981 191 199 6 88 93 1 7000 2134 190 198 7 87 92 6 7500 2286 188 197 8 86 92 1 8000 2438 187 196 9 86 91 6 8500 2591 185 196 0 85 91 1...

Page 8: ...reboot E3 Display Errors Lists up to six codes in order 1 2 3 4 5 6 Newest Last See Error Code Chart for references E4 Reset Errors NO Toggle YES or NO Factory and Service use only Do Not Reset Resett...

Page 9: ...rvice Restart if still fault reload software If mechanical reassemble correctly NO BSKT Insert Brew Basket Brew basket must be in place This is a SAFETY FEATURE Insert brew basket into brewer rails to...

Page 10: ...r use abrasives that will scratch surface Weekly 1 Use a commercial coffee dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning...

Page 11: ...installed filter cartage must be flushed thoroughly prior to connecting it to the brewer to prevent debris from contaminating the machine 6 Verify that the water line will provide a flow rate of at l...

Page 12: ...orm to all local electrical and plumbing codes Installation by unqualified personnel will void the unit warranty and may lead to electric shock or burn as well as damage to unit and or its surrounding...

Page 13: ...able in optional colors Part Number Plug Insert color 1023 00195 00 BROWN PLUG BB HANDLE 1023 00194 00 BLACK PLUG BB HANDLE 1023 00190 00 RED PLUG BB HANDLE 1023 00191 00 GREEN PLUG BB HANDLE 1023 001...

Page 14: ...5151 1104 00061 01 1401 00147 00 1086 00008 00 E115161 1104 00061 01 1401 00159 00 1086 00031 00 E115162 1104 00096 01 1401 00159 00 1086 00031 00 E115180 1104 00095 01 1401 00152 00 1086 00008 00 E11...

Page 15: ...10 00 WASHER 10 SCREW W NEOPRENE BONDED SEAL 26 1 1025 00021 00 TUBE 31 32 OD X 5 8 ID X 4 1 4 LG BREW 27 1 1086 00018 00 HEYCO HOSE CLAMP DIA 875 1 00 28 1 1086 00017 00 HEYCO HOSE CLAMP DIA 1 031 1...

Page 16: ...00008 00 E115261 1101 00339 00 1104 00062 01 1401 00160 00 1086 00031 00 E115262 1101 00339 00 1104 00074 01 1401 00160 00 1086 00031 00 E115280 1101 00339 00 1104 00062 01 1401 00148 00 1086 00008 00...

Page 17: ...AT AND STEM 26 1 1084 00048 00 JAM NUT 1 2 20 UNF NICKEL PLATED BRASS 27 2 1025 00021 00 TUBE 31 32 OD X 5 8 ID X 4 1 4 LG BREW 28 2 1086 00018 00 HEYCO HOSE CLAMP DIA 875 1 00 29 2 1086 00017 00 HEYC...

Page 18: ...WELDMENT WATER LEVEL 2 600 LG 11 1 1023 00171 00 FITTING SINGLE BARBED ELBOW 12 2 1107 00037 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 12 2 1107 00005 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 12 2 11...

Page 19: ...2 1023 00171 00 2X FITTING SINGLE BARBED ELBOW 11 1 1024 00007 00 O RING DASH 344 TANK COVER 12 1 1102 00007 00 TANK COVER ASSEMBLY 13 3 1107 00005 00 HEATER ASSEMBLY IMMERSION 3kW 240VAC 13 3 1107 0...

Page 20: ...C 230 400VAC CE 1 41 20 4 1401 00080 00 E115271 CBS 1152 XV 1or3Ph 3or4 G 3 X 3kW 240VAC 120 208 240VAC E115280 CBS 1152 XV 3Ph 3 G 3 X 3 0kW 240VAC 200VAC J Int 6 5 18 6 1401 00101 00 3 X 3 0 KW E115...

Page 21: ...Go to fetco com for the latest versions of all information Page 21 P167 November 2017...

Page 22: ...Go to fetco com for the latest versions of all information Page 22 P167 November 2017 SKU SKU DESCRIPTION KW Amps Wiring Schematic Heaters...

Page 23: ...0VAC 230VAC CE 1401 00076 00 E115180 CBS 1151 XV 1Ph 2 G 5 0kW 240VAC 200VAC J Int 3 6 17 7 1401 00096 00 1 X 5 0 KW E115190 CBS 1151 XV 1Ph 2 G 4 0kW 240VAC 200 240VAC INTL 4 1 14 2 17 1 1401 00099 0...

Page 24: ...Go to fetco com for the latest versions of all information Page 24 P167 November 2017...

Reviews: