![Fetco CBS-1150 EXTRACTOR V+ User’S Manual & Operator Instructions Download Page 3](http://html1.mh-extra.com/html/fetco/cbs-1150-extractor-v/cbs-1150-extractor-v_users-manual-and-operator-instructions_2285250003.webp)
Go to fetco.com for the latest versions of all information
Page 3
P167 November 2017
Electrical and Output Specifications for CBS-1151 XV+ Single 1½ Gallon-6 Liter Coffee Brewers
USA and Canada
CBS-1151 XV+ Standard-Voltage With cUL/UL and NSF-4 certification
Configuration
Codes
Heater
Configuration
Voltage Phase Wires
Electrical
Connection
KW
Maximum
Amp Draw
Brew-Volume/Hour
(1½ gallon per batch)
E115151
2 X 3.0 kW 208-240
1
2+G
Hardwired
4.6-6.1
22.4-25.8
15.3 gal/58 liters
North America & International Versions
CBS-1151 XV+ With cUL/UL and NSF-4 Certification
E115190
1 X 4.0 kW 200-240
1
2+G
Hardwired
4.1
14.2-17.1
9.3 gal/35 liters
E115191
1 X 5.0 kW 200-240
1
2+G
Hardwired
5.1
17.7-21.3
12.7 gal/48 liters
E115192
2 X 3.0 kW 200-240
1
2+G
Hardwired
6.1
21.3-25.5
15.3 gal/58 liters
E115193
2 X 2.3 kW 200-240
1
2+G
Hardwired
4.7-6.1
22.1-25.5
14.0 gal/53 liters
Export/Japan XV+ With cUL/UL and NSF-4 Certification
E115180
1 X 5.0 kW 200-240
1
2+G
Hardwired 3.6 17.7 11.6
gal/44liters
CE EXPORT/Japan CBS-1151 XV+ With CE and NSF-4 certification. Internal EMI filter. Not cUL and UL listed
(CE) E115162
2 X 2.3 kW 230/400
2
2L,N,
Hardwired
5.6
12.4
14.0 gal/53 liters
(CE) E115161
2 X 3.0 kW 230/400
2
2L,N,
Hardwired
6.1
21.3-25.5
15.3 gal/58 liters
.
Specifications:-Electrical and Output for CBS-1152 XV+ Twin 1½ Gallon-6 Liter coffee brewers
USA and Canada
CBS-1152 XV+ Field Select Electtical With cUL/UL and NSF-4 certification
Configuration
Codes
Heater
Configuration
Voltage Phase Wires
Electrical
Connection
KW
Maximum
Amp Draw
Brew-Volume/Hour
(1½ gallon per batch)
E115251
Selectable
Sold as1 phase
2 X 3.0 kW 208-240
1
2+G Hardwired
4.6-6.1
22.4-25.8
15.3 gal/58 liters
3 X 3.0 kW 208-240
3
3+G Hardwired
6.9-9.1
19.5-22.5
22.5 gal/85 liters
E115252
Selectable
Sold as1 phase
2 X 5.0 kW 208-240
1
2+G Hardwired
7.6-10.1
36.9-42.5
25.3 gal/97 liters
3 X 5.0 kW 208-240
3
3+G Hardwired
11.4-15.1
32.0-36.9
38.3 gal/145 liters
North America & International Versions
CBS-1152 XV+ Standard-Voltage With cUL/UL and NSF-4
tifi ti
E115292
2 X 3.0 kW 208-240
1
2+G Hardwired
4.6-6.1
22.4-25.8
15.3 gal/58 liters
E115294
2 X 5.0 kW 208-240
1
2+G Hardwired
7.6-10.1
36.9-42.5
25.3 gal/97 liters
E115296
3 X 4.0 kW 240/415
3
4+G Hardwired 12.2 15.7-17.1
29.5
gal/112liters
E115290
3 X 3.0 kW
220/380
or
240/415
3
4+G Hardwired
9.1
11.8-12.9
22.5 gal/85 liters
E115291
3 X 5.0 kW
220/380
or
240/415
3
4+G Hardwired
15.1
19.5-21.4
38.3 gal/145 liters
Export/Japan CBS-1152 XV+ With cUL/UL and NSF-4 certification
E115280
3 X 3.0 kW
200
3
3+G
Hardwired
6.5
18.6
17 gal/64 liters
CE EXPORT/Japan CBS-1152 XV+ With CE and NSF-4 certification. Internal EMI filter. Not cUL and UL listed
(CE) E115261
3 X 3.0 kW 230/400
3
3L,N,PE
Hardwired
8.6
12.4
22.5 gal/85 liters
(CE) E115262
3 X 5.0 kW 230/400
3
3L,N,PE
Hardwired
14.1
20.4
38.3 gal/145 liters