13 Warning signals
Warning
signal
Description of warning signal
Cause
Action
Visual
LED [1-15] Flashes green
Battery pack empty.
Charge the battery pack.
Incorrect battery
pack.
Use correct battery pack (see
section
Battery pack too cold.
See battery pack operating man
ual for operating temperature.
Flashes red
Battery pack faulty.
– Change the battery pack.
– Use the charger to check that
the battery pack is fully function
al once it has cooled down.
Lights up red
Cordless mobile dust
extractor overheating
Battery pack over
heating.
Leave the battery pack to cool
for approx. ten minutes.
Water level limit:
Maximum fill level
reached
Acoustic
Signal
Regular
Volume flow below
20 m/s.
Only for dust class M (see sec
tion
).
Increasing, begin
ning with two short
Battery pack charge
low.
– Charge the battery pack.
– Use a newly charged battery
pack.
14 Maintenance and care
WARNING
Risk of injury, electric shock
► Before all maintenance and care work, al
ways remove the battery pack from the
cordless mobile dust extractor.
► All maintenance and repair work which re
quires the motor housing to be opened
must always be carried out by an author
ised service workshop.
Customer service and repairs must
only be carried out by the manufac
turer or service workshops. Find the
nearest address at:
www.festool.co.kr/service
Always use original Festool spare
parts. Order no. at:
www.festool.co.kr/service
EKAT
1
2
3
5
4
► Regularly clean the fill level sensors [9] and
empty the dirt trap [1-9].
Observe the following information:
–
Dust-related inspection (e.g. for filter dam
age, tightness of the machine and function
of the control devices) by the manufacturer
or an instructed person at least once a
year.
–
Dispose of components that cannot be
cleaned. Use impermeable bags to do so.
Observe the applicable disposal provisions!
–
Keep the contacts on the cordless mobile
dust extractor, charger and battery pack
clean.