H-rail mounting

 Mount the H-rail adapter with the included screws (for size 

x

": M4 x 65, 

for size 

¼

": M4 x 77) to the in-line valve VPPM-6L/8L (tightening torque 

approx. 1.5 Nm) 

è

 Fig. 6.

1

2

3

ÓÓ

ÓÓ

ÓÓ

ÓÓ

ÓÓ

ÓÓ

Ô

Ô

4

5

1

H-rail adapter VAME-P1-T

2

In-line valve VPPM-6L/8L

3

Mounting screws

4

H-rail clamping unit

5

H-rail

Fig. 6

 Hang the VPPM-6L/8L onto the H-rail.
 Secure the VPPM-6L/8L with the H-rail clamping (tightening torque 1.5 Nm).

4.2 Pneumatic (in-line valve)

 Attach the pneumatic tubing to the following connections: (

è

 Fig. 4):

– Supply port (1) item 

4

,

 

pressure output (2) item 

2

 Mount a silencer at the exhaust (3) item 

5

 or remove the exhaust air with

ducts.

Operating medium

Note

Too much residual oil content in the compressed air will reduce the service life of
the valve.
 When using bio-oils (oils that are based on synthetic esters or native esters,

e.g. rapeseed oil methyl ester), the maximum residual oil content of 
0.1 mg/m³ must not be exceeded (

è

 ISO 8573-1:2010 [-:-:2]).

4.3 Electrical

Warning

Risk of injury due to electric shock.
 For the electric power supply, use only PELV circuits that ensure a reliable

electric disconnection from the mains network.

 IEC 60204-1/EN 60204-1 to be screwed in.

Note

 Long signal lines pick up more interference. Make certain that the signal lines

are always shorter than 20 m (see also IO-Link specification IEC 61131-9).

 The IO-Link Master may have either port type A or port type B.
 On the device is a 5-pin plug, M12, port type A.
 Use the pre-assembled cable with socket from Festo (accessories

è

 www.festo.com/catalogue). You can then guarantee that the specified

degree of protection IP 65 and EMC are fulfilled.

 The tightening torque of the M12 plug socket with cable must not exceed

0.5 Nm.

 The individual pins on the electrical connection are assigned as follows:

M12 socket, 
(5-pin, A-coded)

Pin

Assignment

Function

1

24 V DC(U

EL/SEN)

Operating voltage supply (PS)

2

n. c.

Not connected

3

0 V DC (U

EL/SEN

)

Operating voltage supply (PS)

4

C/Q

Data communication

5

n. c.

Not connected

Lug (on
the plug)

FE

Functional earth

Fig. 7

5

Commissioning

Note

The VPPM interprets setpoint value specifications that are smaller than 1 % full
scale as 0.

 Connect the VPPM to an IO-Link master or an I-Port master.

– The VPPM communicates with the respective master via the corresponding

protocol. The setpoint and actual values are transferred cyclically, the dia­
gnostic values acyclically.

– The valve has a 16-bit input word (setpoint value) and a 16-bit output word

(actual value).

– If the desired data rate is not set automatically with IO-Link, the data rate can

be forced through a write command to ISDU parameter 0x0048: COM3 = 03,
COM2 = 02. For I-Port, the data rate is always set to COM3.

– Power supply with 24 V DC is provided through the IO-Link master.

 Pressurize the VPPM with an input pressure at least 1 bar higher than the max­

imum desired output pressure. An outlet pressure p2 proportionate to it is then
set. The following outlet pressure is then assigned to the setpoint value signal:

Type code

Outlet pressure
with signal 1 % Full scale

Outlet pressure
with signal 100 % Full scale

VPPM-…-0L2H-…

0.02 bar

2 bar

VPPM-…-0L6H-…

0.06 bar

6 bar

VPPM-…-0L10H-…

0.1 bar

10 bar

Fig. 8

 Select a suitable parameter set (

è

 Chapter 6).

6

Parameterisation

Parameter
number

ISDU
index

Sub-
index

Parameter of the proportional pressure regulator

0

0x043

1

Monitoring parameterisation errors

Activate limit monitoring for the output word

Monitoring of load voltage U

out

/U

val

1

0x043

2

ID (type selection) (read only)

2

0x043

3

Unit for pressure specifications (limit value and current
pressure value)

3

0x043

4

Control behaviour (presets)

Input signal

Measured value smoothing

8 ... 11

0x068

0

Condition counter limit (switching cycle counter)

12

0x069

0

Low byte lower limit value

13

High byte lower limit value

14

0x06A

0

Low byte upper limit value

15

High byte upper limit value

16 ... 19

0x06B

0

Condition counter actual value (updates all 256 steps) is
reset by writing a “0” to 0x68

Fig. 9

Valve parameter: Monitoring

Parameter no.

0

Description

With the proportional pressure regulator, monitoring of individual errors can be
independently  activated or deactivated  (suppressed):
– Monitoring of parameterisation error: Monitors valve parameterisation. An er­

ror message is generated for the following 

implausible 

settings:

Upper limit value ≤ lower limit value
Upper limit value < 0 or > control range (

è

 Fig. 17)

Lower limit value < 0

– Limit monitoring: Defines whether the limit values are monitored, and

a diagnostic message is generated when the limit values are exceeded or
fallen below.

– Monitoring of load voltage: Defines whether the load voltage Uout/U

Val

 is

monitored. If the voltage drops too much (for values 

è

 Technical  data  in

Fig. 25), a diagnostic message is generated.

Active monitoring causes the error to be sent to the IO-Link or I-Port master and
displayed through the Error LED of the VPPM

Bit

Bit 7: Monitoring of parameterisation errors
Bit 6: Limit monitoring
Bit 2: Monitoring of load voltage U

out/val

Values

Bit

7

6

5

4

3

2

1

0

Setting:

0

x

x

x

x

x

x

x

Monitoring of parameterisation errors
inactive

1

x

x

x

x

x

x

x

Monitoring of parameterisation errors
active

x

0

x

x

x

x

x

x

Limit monitoring inactive

x

1

x

x

x

x

x

x

Limit monitoring active

x

x

x

x

x

0

x

x

Monitoring of U

out

/U

val

 inactive

x

x

x

x

x

1

x

x

Monitoring of U

out

/U

val

 active

Comment

Bold = presetting, x = value is unimportant for this setting

Fig. 10

Summary of Contents for VPPM-...-LK Series

Page 1: ...ns Ensure that the compressed air is properly prepared è Technical data Pressurize your entire system slowly There will then be no uncontrolled movements Range of application and certifications In combination with the UL mark on the product the information included in this section is also applicable for compliance with the certification requirements of Underwriters Laboratories Inc UL for USA and ...

Page 2: ...mand to ISDU parameter 0x0048 COM3 03 COM2 02 For I Port the data rate is always set to COM3 Power supply with 24 V DC is provided through the IO Link master Pressurize the VPPM with an input pressure at least 1 bar higher than the max imum desired output pressure An outlet pressure p2 proportionate to it is then set The following outlet pressure is then assigned to the setpoint value signal Type ...

Page 3: ...tting x value is unimportant for this setting Fig 13 Valve parameter Condition counter solenoid coil Parameter no 8 11 Condition counter limit Manual A limit value for a counter condition counter can be set for the internal solenoid coil in the pilot control of the pressure regulator A message is displayed if the limit value is exceeded which is sent to the IO Link master Bytes 11 or 8 High byte o...

Page 4: ...t pressure Failure of data communication Replace data transmission line Fig 24 13 Technical data VPPM 2 bar 29 psi 6 bar 87 psi 10 bar 145 psi Design Proportional pressure regulator Mounting position Any preferably flat display components facing upwards Operating medium Compressed air in accordance with ISO 8573 1 2010 7 4 4 with use of ester oil compressed air in accordance with ISO 8573 1 2010 2...