Assembly instructions (original: de)
8021977
1211NH
†‡
Pressure/intermediate zone
supply module, End plate
VABF-P5-...A3/VABE-P5-C
Festo AG & Co. KG
P.O. box
73726 Esslingen, Germany
+49 711 347-0
www.festo.com
1.
Parts list
18262d_1
Compressed-air supply plate
VABF-P5-P3A3-...
1
Plate
2
Seal
3
M5x12 screw
(1x)
(1x)
(4x)
18262d_3
End plate
VABE-P5-C
1
Plate
2
Seal
3
M5x12 screw
(1x)
(1x)
(4x)
18262d_2
Intermediate zone
supply module
VABF-P5-P1A3-...
1
Plate
2
O-ring
3
M6x20 screw
4
Slot nut
(1x)
(1x)
(2x)
(2x)
1826
2d_6
Not included in scope
of delivery:
5
Mounting rail
(1x)
IPM-PN-08-40x80-AL
As intended:
–
The compressed-air supply plate serves as a lateral supply port and seal
of the mounting rail
–
The end plate serves as seal for the mounting rail
–
The intermediate zone supply module serves as frontal, additional supply
port of the mounting rail.
Note
Select additional accessories from the catalogue
(e.g. mounting plate VAME-P5-MK).
For mounting of the mounting plates (
relevant assembly instructions).
2.
Preassembly (for attachment of an intermediate zone supply module)
Note
To ensure an optimal compressed air supply when an intermediate zone
supply module is used.
Observe that:
–
The intermediate zone supply module
1
should be set as closely as
possible to the centre
–
Several intermediate zone supply modules
1
must be distributed evenly.
The required distance from the mounting plates VAME-P5-MK
(
relevant assembly instructions).
Mark the position for the hole (A).
Drill the corresponding hole (A)
@
12 mm.
Deburr the hole (A).
On each of both sides, cut a thread (M5, depth
›
10 mm) into the
4 holes (B)
Remove all shavings from the mounting rail
5
.
3.
Mounting
3a.
Mounting of the intermediate zone supply module
18262d_7
Note
To avoid mounting problems
during the assembly
sequence:
Remove the slot nuts
4
from the centre of the
mounting rail
5
(
centre hole (A)).
Push the slot nuts
4
into the mounting rail
5
.
18262d_8
Place the O-ring
2
in the
depression in plate
1
.
Position the plate
1
on the
mounting rail
5
until the
hole (A) and thread (C) are
aligned.
Tighten the screws
3
.
Comply with the permissible
tightening torque.
3b.
Mounting of the compressed-air supply plate or end plate
18262d_4
Place the seal
2
in the
opening (D).
Observe thereby the
mounting position
(
magnifying glasses).
Fasten the plates
1
on the
desired side to the mount-
ing rail
5
with screws
3
.
Observe the permissible
tightening torque.
18262d_5
5
1
2
3
1
2
3
1
2
3
4
2 Nm
_
10 %
2 Nm
_
10 %
5
4
A
3
1
2
D
2
1
3
5
B
A
2 Nm
_
10 %
C
3 1
5
2
D