3
System overview
12
Festo – SBRD-EN – 2017-11 – English
–
Digital I/O (24 V I/O with signal specifications).
–
Protocol-based I/O (e.g. fieldbus protocols, graphic displays).
In the run mode, the device performs an evaluation based on the selected job. This results in the follow
ing sequence:
1. Image acquisition with the help of the camera heads.
2. Calculation of the (test) characteristics by the tools.
3. Comparison of the inspection features with the specified tolerance ranges.
4. Output of the results to the digital I/O.
5. Output of the results through the protocol-based I/O.
6. Output of diagnostic data, if applicable.
An evaluation can now be performed.
3.2
Variants
SBRD-Q controller
The SBRD-Q controller is a compact evaluation unit with degree of protection IP 20. Up to 2 cameras of
the SBPB model series can be connected to the device.
Fig. 3.1
SBRD-Q controller
Feature
Code
Value
Control
SBRD
Series D
Function
Q
Quality inspection
Tab. 3.1
Order code