A.3
Address table for Telnet and Telnet-XML
Through Telnet, the following entries can be accessed for reading and/or writing.
The entries have the access type flag word (FW).
Note
Depending on the programming environment, flag word (FW) is also designated
as flagword.
A.3.1
Input register
Name
Read/
Write
FW
Value
Type
Allowed Values
Comments
Trigger signal
R/W
0
Uint16
0 or 1
“Apply Inputs” signal
R/W
1
Uint16
0 or 1
Acknowledge error signal
R/W
2
Uint16
0 or 1
Not used
3
Uint16
Not used
4
Uint16
Not used
5
Uint16
Not used
6
Uint16
Not used
7
Uint16
Job preselection bit 0
R/W
8
Uint16
0 or 1
Takeover of
the preselected job
by setting the input
takeover signal.
The job preselection
is binary coded (bit 0 –
bit 7). Value range
(decimal) 1–255.
During reading, the
currently used job
number is returned.
Job preselection bit 1
R/W
9
Uint16
0 or 1
Job preselection bit 2
R/W
10
Uint16
0 or 1
Job preselection bit 3
R/W
11
Uint16
0 or 1
Job preselection bit 4
R/W
12
Uint16
0 or 1
Job preselection bit 5
R/W
13
Uint16
0 or 1
Job preselection bit 6
R/W
14
Uint16
0 or 1
Job preselection bit 7
R/W
15
Uint16
0 or 1
Tab. A.5
Input register
A.3.2
Output register
Name
Read/
Write
FW
Value
Type
Comments
Ready for operation
R
16
Uint16
Output result OK
R
17
Uint16
Output result not OK
R
18
Uint16
Output result correctly oriented
R
19
Uint16
Output result incorrectly oriented
R
20
Uint16
Configuration mode
R
21
Uint16
Warning
R
22
Uint16