6.3
Assembly with MS-series service unit components
WARNING!
Failure of the safety function.
Incorrect installation in the service unit combination can result in failure of the exhaust safety func-
tion.
•
Only devices that do not impair the exhaust process, even after a possible malfunction of the
device, may be placed downstream from the MS6-SV-….
1 Cover cap MS6-END
2 Module connector
Fig. 15 Assembly
1. Slide the cover cap MS6-END
1
upwards and remove it.
2. Insert a seal
2
between the individual devices (module connector MS6-MV in scope of delivery).
3. Place module connector
2
in the slots of the individual devices.
4. Fasten the module connector with two screws (product scope of delivery). Tightening torque: max-
imum1.2 Nm.
7
Installation
7.1
Pneumatic Installation
Port 1 and 2
If using screw connectors:
–
Note the screw-in depth of the connector thread: 10 mm.
–
Make sure that the compressed air lines are connected correctly.
–
Screw the connectors into the pneumatic connections using a suitable sealing material.
Installation
19
Festo — MS6-SV-...-E-10V24 — 2019-10d