Festo — MS6(N)-SV-...-E-10V24 — 2021-11e
Product overview
9
Automatic start (delivery status) and monitored start
Fig. 2: Operating modes
Operational principle of the multi-pin plug sockets NECA-…-MP1, -MP3 und -MP5
Status of
EN1
Status of
EN2
Status of valve
with NECA-…-
MP1
Status of valve
with NECA-…-
MP3
Status of valve with NECA-…-MP5
0 V
0 V
Unpressurised
Valve switches to
fault mode
Valve does not switch to fault mode,
but remains in the safe, unpressur-
ised status
Note:
Detection of shorts across contacts
and error detection and evaluation
via external controller is required
0 V
24 V
Valve switches to
fault mode
Pressurised
Pressurised
24 V
24 V
Pressurised
Valve switches to
fault mode
Valve does not switch to fault mode,
but remains in the safe, unpressur-
ised status
Note:
Detection of shorts across contacts
and error detection and evaluation
via external controller is required
24 V
0 V
Valve switches to
fault mode
Unpressurised
Unpressurised
Tab. 3: Operational principle of the multi-pin plug sockets NECA