26
Festo — MS6(N)-SV-...-E-10V24 — 2021-11e
Technical data
12
Technical data
12.1
Technical data, mechanical
MS6-SV-E
Type of mounting
In-line installation
with accessories
Design
Piston seat has no underlap
Position sensing principle
Piston magnet principle
Reset method
mechanical spring
Mounting position
any
Sound pressure level
[dB(A)]
75 with silencer UOS-1
Environmental conditions
Shock resistance
Shock test with severity level 2 in accordance with
EN 60068-2-27
Vibration resistance
with severity level 2 in accordance with EN 60068-2-6
Degree of protection
Degree of protection
IP65
Note
with multi-pin plug socket NECA
Materials
Housing
Die-cast aluminium
Seal
NBR
Tab. 9: Technical data, mechanical
12.2
Technical data, pneumatic
MS6-SV-E
Pneumatic port 1, 2
[G]
1/2
Pneumatic port 3
[G]
1
Pilot air supply
internal
Exhaust function
cannot be throttled
Manual override
none
Type of control
piloted
Valve function
3/2-way valve, single solenoid, closed
Soft-start function
Summary of Contents for MS6 SV E 10V24 Series