3
Mounting and installation
Festo – P.BE-MPA-EN – 1309f – English
73
Proceed as follows:
1. Mark all pneumatic tubing.
2. Loosen the clamping screw
1
of the fitting or, if necessary, press down the locking ring of the fit-
ting
2
, e.g. with the QSO releasing tool from Festo.
3. Remove the tubing from the fitting.
1
2
Fig. 3.13 Removing the tubing connection
3.7.3
Common pneumatic lines
Observe the following instructions on installing the pneumatic components. Only then can you guaran-
tee faultless operation.
If there are several systems with centrally ducted exhaust air:
•
Use non-return valves in the common exhaust lines (3/5) or (82/84) in order to pre-
vent functional impairment due to back pressures.
1
2
3
4
5
6
2
2
6
1
First MPA-S valve terminal
2
Common (3/5)
3
Central (82/84)
4
Central (3/5)
5
Second MPA-S valve terminal
6
Common (82/84)
Fig. 3.14 Common lines with non-return valves
Summary of Contents for MPA-S