Technical specifications
Type
HMP-...-AD
HMP-...-EL
Design
Pneumatic end module
Pneumatic-electric end module
Fitting position
On rear end cover of linear module HMP-...
Permitted temperature range
0 ... max. +60
o
C
Protection class as per EN 60529
IP 40
IP 40
Permitted cable cross section
–
0.08 ... max. 0.5 mm
2
/AWG 28-20
Insulation removed
–
5 - 6 mm
Max. permitted bending radius for cable pro-
tection tubing
MKR-...-PG-21
> 45 mm
MKR-...-PG-29
> 50 mm
MKG-20-PG-21
> 130 mm
MKG-23-PG-29
> 155 mm
MKG-37-PG-29
> 205 mm
Materials
End cover:
PA
Window:
PC
Sheet metal angle:
St, galvanized
Adhesive
Fig. 12
0001a
D/GB 11