FDG-...-ZR-RF
Festo FDG-...-ZR-RF 2018-12a English
13
11
Eliminating faults
Fault
Cause
Remedy
Loud running noises and
sluggish slide
Insufficient lubrication of
the slide bearing
Lubricate, if necessary
return to Festo
Red-brown colouring on
the guide rods
Rust due to insufficient
lubrication
Noticeable play on the
slide
Wear, damage
Return product to Festo
Sluggishness of a twin
arrangement near the end
position
Insufficient parallelism
between drive and
FDG-...-ZR-RF
Readjust axes
“Engaging” at a position
long downtime
Disappears after a new
start-up phase
Vibration
Axis overloaded
Observe maximum loading
values
Dynamics too high
Check modifications to
project planning
Incorrect arrangement of
the centre of gravity of the
work load
Shift centre of gravity
External interference on
base stand or in multi-axis
system
Eliminate interference
Missing or undefined
switching functions
Proximity switch or cable
defective
Replace defective part
Sensor support or
switching lug incorrectly
fitted
Correct fitting
Switching gap set
incorrectly
Readjust
Switch or connection
incorrect
Replace incorrect part