Setting the field bus address
(connection point)
The field bus address of the valve terminal
should be set with the two address selector
switches on board 3. The switches are numbe-
red from 0...9. The arrow on the address selector
switches indicates the field bus address set.
PLEASE NOTE
•
Field bus addresses may be assigned only
once per field bus module.
•
Address 0 reserved for the controllers .
•
Address 63 reserved for the programming
terminal.
Proceed as follows:
1. Switch off the power supply.
2. Assign a non-reserved field bus address to
the valve terminal.
3. Use a screwdriver to set the arrow of the re-
levant address selector switch of the desired
field bus address.
VIFB16 - 03/05
3. Installation
0506b
3-11