7 / 52
Festo 7EXCMc_en
1.3
Text designations used in these repair instructions
• Activities that can be carried out in any order.
.
1
Activities which should be carried out in the specified order.
– General lists.
Reference to further information.
Underlined, blue text
indicates a cross-reference or hyperlink that you can click on in the PDF.
1.4
General safety instructions
Danger
Risk of fatal injury due to electric shock and uncontrolled movement of components.
– The planar surface gantry must be de-energised, depressurised and reliably secured against unauthorised
reactivation before the maintenance and repair work begins.
Caution
The planar surface gantry may only be repaired by authorised and trained persons in accordance with the
specifications in the technical documentation and using original spare parts.
Installation and repair by unauthorised and untrained persons, repairs using non-original spare parts or without the
technical documentation required for installation and/or repair are dangerous and therefore not permitted.
Repairs must only be carried out in conjunction with these repair instructions and the respective operating
instructions for the device, as well as the documents listed in
Caution
Unintended switching on can trigger unexpected movements and cause bruises.
–
Ensure that the unit is protected against restarting before any modification or maintenance work or inspections
are carried out. Loosened parts can make unexpected movements or fall off.
– Secure parts against accidental movements or move them into a safe end position.
Note
Observe the given tightening torques. If no special information is given the tightening torques given in the relevant
standard apply to the screws, bolts and nuts used.
Note the strength class of the screws, bolts and nuts!
Festo recommends use of LOCTITE 243 thread locking agent.
In the event of damage caused by unauthorised manipulation, improper use or use of non-original spare parts, all
warranty and liability claims against the manufacturer expire.
Instead of carrying out the repair yourself, your local Festo sales office offers the option of having the repair carried
out by Festo.
Components and equipment replaced during repair must be disposed of in accordance with the relevant local
environmental protection regulations.
Summary of Contents for EXCM-10
Page 1: ...Repair instructions en 7EXCMc_en Planar surface gantry EXCM 10 30 ...
Page 16: ...16 52 Festo 7EXCMc_en 3 1 EXCM 10 components overview ...
Page 18: ...18 52 Festo 7EXCMc_en 3 2 Components overview EXCM 30 Product series up to H7 July 2016 ...
Page 20: ...20 52 Festo 7EXCMc_en 3 3 Components overview EXCM 30 Product series from H8 August 2016 ...
Page 22: ...22 52 Festo 7EXCMc_en 3 4 Component overview EXCM 30 P8 Product series from H8 August 2016 ...