Technical Data
Technical data
Input voltage, L1/L2/L3
3 x 400 V AC ±10%
Input frequency
50 to 60 Hz
Maximum current, L1/L2/L3 connection
16 A, must be protected by back-up fuse
Rectifier input voltage (T1/T2)
Max. 230 V AC
Rectifier output voltage T1
Approx. 10 to 230 V DC rms
Rectifier output voltage T2
210 V DC rms
Maximum current of CD outputs
4 A, not protected
Potentiometer fuse
Resettable 4 A fuse
Protection class
1, operation with protective grounding
Overvoltage category
II, operation in building installations
Degree of contamination
2, laboratory environment
Electrical connections
Safety laboratory cables per EN 61010-031, min. conductor cross-section 1 mm²
Operating temperature range
5 to 40° C / 100%
Max. relative humidity
80 %
Degree of protection
IP 20 (not attached to the mounting frame)
Device operation
Use only indoors, max. altitude: 2000 m above sea level
Dimensions
(H x W x D in mm)
297 x 266 x 140
Weight
4 kg
Certifications
CE marking per
The Low Voltage Directive