DMSP/MAS
28
Festo – DMSP/MAS – 1508e English
14
Characteristic curves
Permissible force F [N] dependent on the contraction h [% of the nominal length]
(nominal length = visible area of the load-free contracting diaphragm)
Note
Deviation of the theoretical force up to 10 %.
The actual force dependent on the contraction can vary according to the following char
acteristics:
–
material
–
production variation
–
nominal length
The deviation can be compensated if the pressure is adapted up to the maximum per
missible operating pressure.
DMSP-5
0 bar
1 bar
2 bar
3 bar
4 bar
5 bar
6 bar
1
Max. pretensioning
2
Max. permissible contraction
3
Theoretical force (140 N) at max. operating pressure
Permissible work space with
DMSP-5
Fig. 9
Summary of Contents for DMSP Series