background image

7.2 Direct mounting

Fig. 4 

1.

Attach drive paying attention to the minimum number of screws used in pairs
(in this example: 2 pairs of screws): 
– On the bores in the profile or cover (with DLGF)
– On the bores in the cover (with DLGF­...­W)
Maintain a maximum support clearance of 300 mm at all times. With
DLGF­...­W where necessary provide external support (e.g. from the machine
frame).

2.

Tighten screws uniformly to the following tightening torque.

DLGF-...

20

25

32

40

Minimum number of pairs of screws depending on stroke

50 … 150

[mm]

2

2

2

2

200

[mm]

2

2

2

3

250

[mm]

2

2

3

3

300

[mm]

3

3

3

3

350 … 450

[mm]

3

3

3

4

500 … 600

[mm]

4

4

4

4

650 … 750

[mm]

4

4

4

5

800 … 1000

[mm]

5

5

5

5

Screw size and tightening torque

Bolt

M4

M5

M6

M6

Tightening torque

[Nm]

2.5 ± 10 %

5.8 ± 20 %

7.7 ± 20 %

8.2 ± 10 %

Tab. 1

7.3 Attachment

Fig. 5 

NOTICE!

A warped attachment component bends the slide and shortens the service life of
the guide.
• Use an attachment component with an even surface.

Flatness with recirculating ball bearing: t = 0.01 mm

– Position the payload in such a way, that the break­down torque (parallel to the

axis of motion) and lever arm remains as low as possible. 

– Avoid collisions of tool and payload with attachments. 
– For attachment components with their own guide:

Adjust the guides of the tool and drive so that they are exactly parallel, or use a
connection that permits tolerance compensation. In this way, the guide is not
overloaded.

On DLGF-G in basic version:

Attach mounting element (e.g. moment compensator DARD­L8) to slide with
screws. 

Fig. 6 

DLGF-G-...

20

25

32

40

Screw S

M4

M4

M4

M4

Tightening torque M

[Nm]

3 ± 10 %

3 ± 10 %

3 ,4± 10 %

3 ,4± 10 %

Tab. 2

On DLGF-KF with recirculating ball bearing:

Fasten the attachment to the slide with screws and centring elements. Pay
attention to the maximum screw­in depth  D and the tightening torque. 

Attachment of mounting component from above/front:

Fig. 7 

DLGF-KF-...

20

25

32

40

Mounting from above

Screw S

1

M4

M5

M5

M6

Max. screw­in depth D

1

[mm]

8.8

9.8

10.3

10.3

Tightening torque M

1

[Nm]

2.2

4.5

4.5

7.5

Centring H7

[mm]

Æ

 7

Æ

 9

Æ

 9

Æ

 12

Mounting from front

Screw S

2

M3

M4

M3

M4

M4

M5

M4

M6

Max. screw­in depth D

2

[mm]

7

7

7

9

7.5

10

8

10

Tightening torque M

2

[Nm]

1

2.2

1

2.2

2.2

4.5

2.2

7.5

Tab. 3

7.4 Mounting accessories

Position scanning with proximity sensors:
– Press proximity switch into the grooves 

7

 

è

5.2 Layout. 

– Avoid external influences from magnetic or ferritic parts in the vicinity of the

proximity sensors (maintain a minimum distance of 10 mm).

– To avoid contamination, use groove covers on all unused grooves

è

 www.festo.com/catalogue.

To set the speed:
– Use one­way flow control valves in the supply ports.

To secure the payload from dropping when a pressure failure occurs:
– Use check valves.

Reviews: