3. Diagnosis and error treatment
3−8
Festo P.BE−CPX−FB23−EN en 0308NH
3.3.2
CPX−specific LEDs
PS (power system) power sensor/logic supply
LED (green)
Sequence
Status
Meaning/fault treatment
LED lights up
ON
OFF
No fault Operating voltage/
sensor supply applied
LED flashes
ON
OFF
Operating voltage/sensor
supply outside the toler
ance range
Eliminate undervoltage
LED flashes
ON
OFF
Internal fuse for the
operating voltage/sensor
supply has responded.
1. Eliminate short circuit/overload on
module side.
2. Depending on the parametrizing of
the module (module parameter):
·
The sensor supply voltage is
automatically
switched on again
when the short circuit has been
eliminated (default)
·
Power Off/On is necessary
The LED is out
ON
OFF
The operating voltage/
sensor supply is not
applied
Check the operating voltage connec
tion of the electronics.
PL (Power Load) power load supply (outputse/valves)
LED (green)
Sequence
Status
Meaning/fault treatment
LED lights up
ON
OFF
No fault Load voltage
applied
None
LED flashes
ON
OFF
Load voltage at the system
supply or additional supply
outside the tolerance
range
Eliminate undervoltage
Summary of Contents for CPX-FB23
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE CPX FB23 EN en 0308NH...
Page 15: ...Installation 1 1 Festo P BE CPX FB23 EN en 0308NH Chapter 1...
Page 45: ...Commissioning 2 1 Festo P BE CPX FB23 EN en 0308NH Chapter 2...
Page 86: ...2 Commissioning 2 42 Festo P BE CPX FB23 EN en 0308NH...
Page 87: ...Diagnosis and error treatment 3 1 Festo P BE CPX FB23 EN en 0308NH Chapter 3...
Page 104: ...3 Diagnosis and error treatment 3 18 Festo P BE CPX FB23 EN en 0308NH...
Page 105: ...Technical appendix A 1 Festo P BE CPX FB23 EN en 0308NH Appendix A...
Page 117: ...Index B 1 Festo P BE CPX FB23 EN en 0308NH Appendix B...
Page 118: ...B Index B 2 Festo P BE CPX FB23 EN en 0308NH Contents B Index B 1 B 1 Index B 3...