Festo control block CPX-CEC
3.7
Connecting a handheld CPX-MMI
The 5-pin M12 socket is used for connecting a CPX-MMI for fast preliminary commissioning, diagnosis or
parameterisation.
Figure: CPX terminal with handheld CPX-MMI
The connection to the CPX-MMI is interrupted while downloading a program if parameters were changed
via Codesys. This guarantees the consistency of the displayed data.
Use only the following original cables to connect the CPX-MMI
(
www.festo.com/catalogue):
Order code
Cable length
KV-M12-M12-3,5
3.5 m
KV-M12-M12-1,5
1.5 m
Table: Connecting cables for handheld CPX-MMI
Further information:
section Parameterisation using the handheld CPX-MMI.
General information on the CPX-MMI can be found in the manual P.BE-CPX-MMI-1-...
3.8
Ensuring protection to IP65/IP67
In order to ensure protection to IP65/IP67, seal unused sockets and the switch with the appropriate covers:
Connection/switch
Connection to IP65/IP67
Cover
1)
to IP65/IP67
Ethernet, RJ45
Plug FBS RJ45-8-GS
Cover
2)
AK-RJ45
Sub-D (CANopen/RS232) and
DIL switch
Plug FBS SUB-9-BU-2x5Pol-B
Transparent cover
2)
AK-
SUB-9/15-B
Service interface, M12
Connecting cable and plug of the
CPX-MMI
Protective cap
2)
ISK-M12
Rotary switch
Cover
2)
AK-RJ45
1) if connection is not used
2) included in the scope of delivery
Table: Connections and covers for protection to IP65/IP67