CPE...-PRS...
Festo CPE...-PRS 2017-12f English
9
In order to dismantle linked CPE...-PRS...:
1. Remove the CPE valves.
2. Press down the locking nose
5
and pull the valve slide completely away from
the sub-base.
3. Dismantle the individual parts in the reverse order to fitting.
Dismantling from a hat rail
1. Remove the CPE valves.
2. Loosen the locking screws.
3. Dismantle linked CPE...-PRS-... .
4. Use a screwdriver to lift up the fastening
slides of the individual sub-bases.
7
Accessories
Designation
Type
Blind plate
CPE-...-PRSB
Designation signs
IBS 6 x 10
Fig. 13
Fig. 12
5