Festo — CMMT-AS-C2/3/5/7/12-11A-P3-... — 2021-12e
Product overview
17
4.2.2
Overview of connection technology
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Fig. 4: Connections of the CMMT-AS-C2-11A-P3 (example)
1
PE connection, housing
2
[X9A] Mains and DC link circuit connection
3
[X9C] Logic voltage
4
[XF2 OUT] RTE interface port 2
5
[XF1 IN] RTE interface port 1
6
[X1C] inputs/outputs for the axis
7
[X6B] motor auxiliary connection
8
[X6A] motor phase connection
9
Shield clamp of motor cable
10
[X2] encoder connection 1
11
[X3] encoder connection 2
12
[X10] device synchronisation
13
[X18] standard Ethernet
14
[X5] connection for operator unit (behind
the blind plate)
15
[X1A] I/O interface
16
[X9B] connection for braking resistor