6. Control via FHPP
70
Festo.P.BE-CMMP-CAM-SW-EN en 1105a
6.4
Overview: assignment of the control bytes and status
bytes
6.4.1
Control bytes
CCON
B7
B6
B5
B4
B3
B2
B1
B0
OPM2
OPM1
LOCK
RESET
BRAKE
STOP
ENABLE
Operating mode
selection
Block MMI
access
–
Reset fault
Release
brake
Stop
Enable drive
CPOS
B7
B6
B5
B4
B3
B2
B1
B0
CLEAR
TEACH
JOGN
JOGP
HOM
START
HALT
–
Delete
remaining
path
Teach
value
Jog
negative
Jog
positive
Start
homing
Start
positioning
job
Halt
CDIR *)
B7
B6
B5
B4
B3
B2
B1
B0
FUNC
FGRP
FNUM
COM2
COM1
ABS
Execute
function
Function group
Function number
Control mode
(position, force …)
Absolut
e/Relati
ve
*) only for direct operation. In the case of record selection, the record number is transferred in
control byte 3. The function of CDIR then takes over PNU 401 + subindex.