4. Concepts of the cam disc
49
Festo.P.BE-CMMP-CAM-SW-EN en 1105a
In the following example, cam switch no. 1 has two cams: The first cam is actuated when
the X-position lies between 1 and 2, the second cam when the X-position lies between 3
and 4.
The cams can either be interrogated via FHPP or mapped onto digital outputs.
Interrogation via FHPP:
You can read the status of the cams
(actuated/not actuated) out of the PNU 311/02.
See FHPP description according to section 1.3 Documentation
overview CMMP-AS.