B.1
General FHPP parameter structure
The motor controller includes a parameter set with the following structure.
Group
PNU range
Description
Page
Device data
100 … 199
Device identification and device-specific settings, e.g.
version numbers.
Diagnostics
200 … 299
Diagnostic events and diagnostic memory. Fault num
bers, timestamp, incoming/outgoing event.
Process data
300 … 399
Current setpoint and actual values, local digital in
puts and outputs, e.g. status data.
Record list
400 … 499
A record includes all the setpoint value parameters
required for a positioning procedure.
Project data
500 … 599
Fundamental project settings, e.g. maximum speed,
acceleration, deceleration, project zero point offset.
These parameters are the basis for the record list.
Factor group
600 … 699
Parameters for unit conversion.
Axis data: electric
drives 1
1000 … 1099
All axis-specific parameters for electric drives, e.g.
gear ratio, feed constant, reference parameters.
Tab. B.1
FHPP parameter structure